Comfort-Aire RSN13-Dry-R-22-Series User Manual

Page 2

Advertising
background image

2

Figure 1. Digital Thermostat

Fan

Mode

Temperature

Selector

System

Mode

ABOUT THE AIR CONDITIONER

This split system cooling unit has been designed and built
to provide many years of safe and dependable comfort,
providing it is properly installed and maintained. With
regular maintenance, this unit will operate satisfactorily
year after year. Abuse, improper use, and/or improper
maintenance can shorten the life of the appliance and
create unsafe hazards. A regular service and maintenance
schedule should be established to ensure efficient and
safe operation of the unit.

OPERATING INSTRUCTIONS

Thermostat styles vary. Some models may not include
the AUTO mode and others will have the AUTO in place
of the HEAT and COOL. Others may include all three.
Please refer to the thermostat’s User Manual for detailed
programming instructions.

The thermostat should be mounted about 5 feet above the
floor on an inside wall and not on an outside wall or other
location where its operation may be adversely affected by
radiant heat from fireplaces, sunlight, or lighting fixtures,
and convective heat from warm air registers or electrical
appliances.

Cooling Operation

1. Set the thermostat’s system mode to COOL or AUTO

and change the fan mode to AUTO. See Figure 1.

2. Set the temperature selector to the desired

temperature level. The outdoor fan, compressor, and
blower motor will all cycle on and off to maintain the
indoor temperature at the desired cooling level.

NOTE: If the temperature level is re-adjusted, or the
system mode is reset, the fan and compressor in the
outdoor unit may not start immediately. A protective
timer circuit holds the compressor and the outdoor fan
off for approximately 5 minutes following a previous
operation or the interruption of the main electrical
power.

Heating Operation

1. Set the thermostat’s system mode to HEAT or AUTO

and change the fan mode to AUTO. See Figure 1.

2. Set the temperature selector to the desired

temperature level. The optional heating equipment
(furnace or electric heat) will cycle on & off to maintain
the indoor temperature at the desired heating level.

Operating the AC for Automatic Cooling &
Heating

1. Set the thermostat system mode to AUTO and the

thermostat fan mode to AUTO. See Figure 1.

2. Set the thermostat temperature selector to the

desired temperature level. The thermostat will
maintain the desired temperature level by switching
between either the outdoor cooling unit or the indoor
heating unit (furnace or electric heat) automatically.

Operating the Indoor Blower Continuously

The continuous indoor blower operation is typically used
to circulate the indoor air to equalize a temperature
unbalance due to solar loads, increased occupancy loads,
or mechanical equipment operation. Set the thermostat
fan mode to ON (Figure 1). The indoor blower starts
immediately, and will run continually until the fan mode
is reset to AUTO.

NOTE: The continuous indoor blower operation can be
obtained with the thermostat system mode set in any
position, including OFF.

Turning the Air conditioner Off

Change the thermostat’s system mode to OFF and the fan
mode to AUTO (See Figure 1).

NOTE: The system will not

operate, regardless of the temperature selector setting.