Fixed wall mount option–installation – Comfort-Aire IRGPH15B User Manual

Page 4

Advertising
background image

Owner’s Manual

Glass Panel Heater

Heat Controller

4

ELECTRICAL CONNECTION

PORTABLE FLOOR MOUNT OPTION–INSTALL SUPPORT FEET

1. The wall brackets supplied with the heater must be

used for the wall mount option

2. The heater should be positioned observing the

minimum clearances stated around the heater:

MINIMUM CLEARANCES (SEE FIG 1) :
From top surface of heater

18” (450mm)

From side of heater

10” (250mm)

From bottom of heater

6” (150mm)

Do not locate the heater where a draft may affect

the ambient temperature readings, and thus the

controll setting.

3. First remove the wall bracket from the rear housing

of the heater. Unscrew the (2) screws located on

the top of the two vertical bars of the wall bracket

(see Step1 on page 3).

4. Pull out the top of the bar by pressing firmly on both

upper tabs slotted into the rear housing (Step 2).

5. Slide the wall bracket down to remove it from the

rear housing (Step 3).

6. Fix the wall bracket securely to the wall through

the (4) screw holes provided. Use wall anchors if

necessary (not provided).

7

.

Hold the heater in the upright (vertical) position.

and position the top of heater against the wall

bracket. Push the bottom slots on the heater’s

back enclosure onto bottom tabs on the vertical

bracket bars. Pull up on the heater to seat the

heater onto the bracket.

8. Push the heater toward the top of the bracket’s

vertical bars, firmly seating the bracket tabs into

the top slots on the back of the heater enclosure.

Tighten the (2) screws on the top of the bracket’s

vertical bars to lock the heater to the mounting

bracket (Step 4).

FIXED WALL MOUNT OPTION–INSTALLATION

1. Turn the heater upside down begin assembly of the

two support feet by unscrewing the wing-nuts.

2. Position the support feet with the longer section at

the rear of the heater as shown (Fig.1-2)..

3. Reinstall the wing nuts and be sure both wing-nuts

are tightened firmly and the casters on the feet are

secure.

4. Turn the heater upright before operating it.

• The heater must be powered with 120V 60Hz

single phase current.

• The power outlet must be properly polarized and

grounded. Use of a ground fault circuit interrupter

(GFCI) is always recommended

• The proper electrical outlet, circuit breaker, etc.,

must be installed by a qualified electrician.

• Use of an extension cord is not recommended.

REAR

Advertising