8

Fault

Possible Cause

Solution

Machine does not start

Interruption in the power supply

Check the power supply; ensure the plug is switched on. Have the power circuit tested

by a qualified electrician

The power cable or mains plug is

defective

Have the power cable replaced by an authorised Silverline service centre

The on/off trigger switch is defective

Have the switch replaced by an authorised Silverline service centre

Construction site generator in sleep mode

Activate generator

Voltage from generator too low or

incompatible with this machine

This machine may be incompatible with this specific power source

No hammering action

The machine is too cold

Have the machine warm up, then run it under no load to warm up the oil and loosen up

the internal mechanisms

Insufficient lubrication

Check oil level (see ‘Maintenance’) and top up if appropriate. Running the tool with

insufficient lubrication may have caused tool damage, in which case the machine needs

to be repaired by an authorised Silverline service centre

A fault has occurred in the machine

Have the tool repaired by an authorised Silverline service centre

The machine does not

operate at full power

The extension lead is too long or of

inadequate cross section

Use a suitable extension lead

The voltage provided by the power

supply is too low

Check power supply and change to a different circuit if possible

A fault has occurred in the machine

Have the tool repaired by an authorised Silverline service centre

Oil is leaking from the

machine housing

Seals missing/damaged

If occurring after an oil service or top-up, check the seals underneath the covers that

had been removed during service. Otherwise, have the tool repaired by an authorised

Silverline service centre

Troubleshooting

GB

263570_Z1MANPRO1.indd 8

24/09/2013 17:40