Rs485 connection with full duplex, Multi-drop network (daisy chaining) – RMS Technologies ACC-03 RS485 TO RS232 CONVERTER CARD (ROHS) User Manual

Page 6

Advertising
background image

RS485 Connection with full duplex

If your RS485 device is a full duplex, or 4-wire device, below is the
recommended connection to the RS485-232 converter card.

120 Ω

120 Ω

RS485 Full duplex

RS485 Converter

card

Figure 4: Full duplex conneciton


Multi-drop network (Daisy Chaining)


In order to communicate to multiple units at once, combine all three RS485

communication wires in parallel as shown below:

RS485 Converter
Card

Figure 5: Multi-drop connection

RS485-232 Converter Card