02/13/2006

Recommended Cable Configurations: Driver to Motor

Cable length, wire gauge and power conditioning devices play a major role in the performance

of your Driver and Motor.


NOTE: The length of the DC power supply cable between the Driver and the Motor should not

exceed 50 feet.


Example A demonstrates the recommended cable configuration for the Driver to Motor cabling

under 50 Feet long.


If cabling of 50 feet or longer is required, the additional length can be gained by adding

Common Mode Line Filters (2x)


*L ≈ 0.5 MH

* 0.5 MH is a typical starting point for the Common Mode Line Filters. By increasing or

decreasing the value of L you can set the drain current to a minimum to meet your

requirements.