Preparing your saw for use, Preparing y our saw – SawStop 3.0HP User Manual

Page 37

Advertising
background image

SawStop 10” Professional Cabinet Saw 35

Preparing Y

our

Saw

Preparing Your Saw for Use

Fig. 52

motor

Attempting to operate the Professional Cabinet Saw model PCS31230 with power other than 208-240V
single phase power will void all warranties and may result in serious injury as well as damage to, or a malfunction
of, the saw or safety system.

Electrical Power Connection for a 208-240V, 3 hp Saw (PCS31230)

The Professional Cabinet Saw model number PCS31230 comes with an AC motor that is rated at

3 hp

and

operates at 60 Hz. It can be used w

ith single phase 208-240V

power. The motor draws 13

amps

at 208-240V

power. Do not us

e any other motor to power your saw.

The Professional Cabinet Saw model PCS31230 is shipped with a 9 ft power cord that has a NEMA 6-15P
plug designed for use with matching single phase

230V, 60Hz

power outlets. If you need a longer cord, or if

you need to replace the plug with a different style of plug designed for 208-240V, follow the instructions on
page 36.

WARNING! Do not connect the saw to electrical power until the saw is
completely assembled and you have read and understood this entire manual.

WARNING! This saw must be connected to a grounded wiring system, or to a system having an equipment-
grounding conductor. Failure to connect this saw to an adequate electrical ground may cause the safety
system to malfunction and could result in a serious injury or electric shock.

Advertising