Aqua Bath CP6030TD User Manual

Page 6

Advertising
background image

1. Product Name
QUIKRETEª Non-Shrink Precision Grout #1585-00

2. Manufacturer
The QUIKRETE Companies
One Securities Centre
3490 Piedmont Rd., NE, Suite 1300
Atlanta, GA 30305

(404) 634-9100

Fax: (404) 842-1424
www.quikrete.com

3. Product Description

BASIC USE
Typical applications for QUIKRETE Non-Shrink
Precision Grout include grouting of:
• All types of machinery
• Steel columns
• Bearing plates
• Precast concrete
• Other anchoring conditions that require

high in-service strength

The nonshrink characteristics of Non-Shrink
Precision Grout make it stable and capable of
handling high load transfers.

COMPOSITION & MATERIALS
QUIKRETE Non-Shrink Precision Grout is a non-
metallic Portland cement based material.
Non-Shrink Precision Grout is a preblended
product including expansive additives, requiring
only the addition of water to obtain flowable
properties and high strengths.

SIZES
• 50 lb (22.7 kg) bags

COLORS
• Gray

YIELD
A 50 lb (22.7 kg) bag of QUIKRETE Non-Shrink
Precision Grout will yield 0.45 cu ft (12.7 L) at
flowable consistency.

LIMITATIONS
The proper cleaning and wetting of surfaces to
be grouted is vital to maximum performance.
Hot and cold temperature precautions, as they
apply to concrete, should also be followed.

4. Technical Data

APPLICABLE STANDARDS
ASTM International
• ASTM C109/C109M Standard Test Method for

Compressive Strength of Hydraulic Cement
Mortars (Using 2-in. or [50-mm] Cube
Specimens)

• ASTM C939 Standard Test Method for Flow of

Grout for Preplaced-Aggregate Concrete
(Flow Cone Method)

• ASTM C1090 Standard Test Method for

Measuring Changes in Height of Cylindrical
Specimens from Hydraulic-Cement Grout

• ASTM C1107 Standard Specification for

Packaged Dry, Hydraulic-Cement Grout
(Nonshrink)

• ASTM E488 Standard Test Methods for

Strength of Anchors in Concrete and
Masonry Elements

U.S. Army Corps of Engineers (USACE) - CRD 621

PHYSICAL/CHEMICAL PROPERTIES
QUIKRETE Non-Shrink Precision Grout complies
with all properties of ASTM C1107 and CRD 621
producing the results shown in Table 1.

5. Installation

MIXING
QUIKRETE Non-Shrink Precision Grout should be
mechanically mixed for a minimum of 5 minutes.

PRECAUTIONS
Add the minimum amount of water necessary
to produce the desired flow characteristics as
indicated in Table 2. Do not exceed a flow of
20 seconds per ASTM C939.

METHODS
Surfaces to receive the grout must be clean
and free of any type of foreign matter, grease,
paint, oil, dust or efflorescence. In some cases it
may be necessary to roughen smooth surfaces
or etch old ones with acid. The area should be
flushed and soaked with clean water prior to
grouting leaving no standing water. Place the

GROUTS

03600

The QUIKRETE Companies

®

SPEC-DATAª and MANU-SPECª are registered trademarks of Reed Elsevier Inc. The ten part SPEC-DATA format conforms to the editorial style

of The Construction Specifications Institute and is used with their permission. The manufacturer is responsible for technical accuracy. ©2005 Reed Construction Data. All Rights Reserved.

TM

TABLE 1 TYPICAL PHYSICAL PROPERTIES AT 73°F (23°C)

Compressive strength, ASTM C109 modified per
ASTM C1107

Plastic consistency

1 day

3000 psi (20.7 MPa)

3 days

9500 psi (65.5 MPa)

7 days

10,000 psi (68.9 MPa)

28 days

14,000 psi (96.5 MPa)

Height change, ASTM C1090
1, 3, 7 and 28 days

0 - 0.2%

Flowable consistency

1 day

3000 psi (20.7 MPa)

3 days

9000 psi (62.1 MPa)

7 days

9500 psi (65.5 MPa)

28 days

12,500 psi (86.2 MPa)

Height change, ASTM C1090
1, 3, 7 and 28 days

0 - 0.2%

Fluid consistency

1 day

2500 psi (17.2 MPa)

3 days

5000 psi (34.5 MPa)

7 days

6000 psi (41.4 MPa)

28 days

8000 psi (55.2 MPa)

Height change, ASTM C1090
1, 3, 7 and 28 days

0 - 0.2%

Pull-out strength,

35,000 psi (241 MPa)

ASTM E488

1

1

1 1/4" (31 mm) bolts embedded 9" (225 mm) deep in 3" (75 mm)

hole in 2000 psi (13.8 MPa) concrete.

TABLE 2 APPROXIMATE WATER REQUIRED FOR 50 LB
(22.7 KG) OF GROUT

Plastic

1 gal (3.8 L)

Flowable

1 gal + 1 pt (4.3 L)

Fluid

1 gal + 3 pt (5.2 L)

TABLE 3 WORKING TIME

Temperature

Working time

50°F (10°C)

25 min

73°F (23°C)

25 min

90°F (32°C)

15 min

QUIKRETEª Non-Shrink Precision Grout #1585-00