Read air motor label to check that
motor has been designed for use
in a hazardous application:
• Hazardous zone
• Hazardous category
• Equipment group
• Temperature class
• Maximum surface temperatures

Example:
Model designation: 1UP-NRV-10
Year manufactured: 2003

Gast Mfg. Corp.

II 2GD c T5 *
Benton Harbor, MI USA
Telephone: 269.926.6171

* Legend:
II Equipment group II
2 Equipment category 2
G Gas atmospheres
D Dust atmospheres
c Constructional safety
T5 Max. surface temp. 212ºF/100ºC

Your safety and the safety of others

is extremely important.

We have provided many important safety messages
in this manual and on your product. Always read
and obey all safety messages.

This is the safety alert symbol. This symbol

alerts you to hazards that can kill or hurt you and
others. The safety alert symbol and the words
“DANGER” and “WARNING” will precede all safety
messages. These words mean:

You will be killed or seriously injured if you don’t
follow instructions.

You can be killed or seriously injured if you don’t
follow instructions.

All safety messages will identify the hazard, tell you
how to reduce the chance of injury, and tell you
what can happen if the safety instructions are not
followed.

Correct installation is your responsibility. Make sure
you have the proper installation conditions.

INSTALLATION

WARNING

DANGER

WARNING

Injury Hazard

Install proper guards around output shaft as
needed.

Air stream from product may contain solid or liquid
materials that can result in eye or skin damage.

Wear eye protection when installing this product.

Failure to follow these instructions can result in
serious injury or property damage.

2

CODE SYMBOLS

Hazard.

Possible consequences: death or

severe injuries.

Hazardous situation.

Possible

consequences: slight or mild injuries.

Dangerous situation.

Possible

consequences: damage to the drive or the
environment.

Important instructions on protection
against explosion.

Application tips and useful
information.

Improper environment, installation and operation
can result in severe personal injury and/or damage
to property.

Qualified personnel must perform all work to
assemble, install, operate, maintain and repair air
motor.

Qualified personnel must follow:

• These instructions and the warning and information

labels on the motor.

• All other drive configuration documents, startup

instructions and circuit diagrams.

• The system specific legal regulations and

requirements.

• The current applicable national and regional

specifications regarding explosion protection,
safety and accident prevention.

Complete the following checklist prior to
starting installation in a hazardous area. All

actions must be completed in accordance with
ATEX 100a.

Check the site environment for potentially
explosive oils, acids, gases, vapors or radiation

Check the ambient temperature of the site and
the ability to maintain proper ambient
temperature.
Ambient range:
Normal conditions: 34ºF/1ºC to 250ºF/121ºC
Hazardous conditions: 34ºF/1ºC to 104ºF/40ºC

Check the site to make sure that the air motor
will be adequately ventilated and that there is
no external heat input (e.g. couplings). The
cooling air may not exceed 104ºF/40ºC.

Check that products to be driven by the air
motor meet ATEX approval.

Check that the air motor is not damaged.

Checklist for installation in hazardous areas: