ConTech Lighting LVR316 User Manual

ConTech Lighting For the car

Advertising
background image

2

INSTALLATION PROCEDURES

Do not install insulation within 3" of the housing. (Figure 1)
Cut the plastic retaining strap off the transformer/junction box mounting plate

assembly.
Remove the transformer/junction box on the mounting plate assembly from

the junction box.
Remove a knockout from the junction box for the supply wires before

mounting the transformer plate back on the junction box.
To mount the recessed fixture to the ceiling structure, extend the adjustable

bar hangers and firmly mount to the ceiling joist support members.
NOTE: When installing to a wood joist, the convenient mounting spikes may

be used to hold the hanger bars temporarily in place. The installation must be

completed with proper fasteners (not provided).
Screw or nail the bar hangers sercurely to the wood joists. T-Bar cutouts are

provided in the bar hangers.

ELECTRICAL CONNECTIONS

Connect the 3/8" or 1/2" size flexible conduit (black, white and green 120V

supply wires) to the junction box with a suitable connector.
Connect black to black (hot), white to white (neutral), and green to green

(ground) with twist type wire connectors (not provided). (Figure 2)
Replace the junction box cover by setting the plate base into the holder and

locking at the side with the spring clip. Ensure that all wires are safely within

box before closing.
Position the housing so that the rim is flush with the finished ceiling. The

recessed housing is adjustable vertically (held in place by [3] spring clips).
Place the tempered glass lens (supplied with the trim) into the lamp cradle

and properly seat the lamp between the spring retainer and the clear

tempered lens. NOTE: Handle the MR16 lamp only by the socket or rim.

Never touch the interior portion. If the electrician or designer decides to use a

front glass MR16 lamp, the standard clear tempered safety lens should not be

used. Use of both will cause excessive heating and void the factory warranty.
Firmly press the lamp pins or the lamp socket leads from the trim into the

two holes in the ceramic terminal block socket. Tighten the two straight

blade retaining screws in the ceramic terminal block socket. Tuck the

combined wire leads out of the way into the housing cavity.
Set the two or three trim mounting springs into the housing opening and push

up until the trim is seated firmly to the ceiling surface. After the trim is

inserted fully, give it a quarter turn to secure it into place.
NOTE: If the recessed housing is going to be controlled by a dimmer, only

use dimmers rated for low voltage magnetic transfomers.

IMPORTANT SAFETY INSTRUCTIONS:

• Read all the instructions before installation. Save instructions for later use.

• Turn off power at fuse or circuit breaker box before installation or before

doing any maintenance work.

• Product must be grounded to avoid potential electric shock and any other

potential hazards.

• Product must be mounted in locations and at heights and in a manner

consistent with its intended use, and in compliance with National Electrical

Code and local codes. Use of accessory equipment is not recommended.

• Installing contrary to instructions may cause unsafe conditions.

• Do not block light from the trim aperture, in whole or in part, as this may

cause unsafe conditions.

Warning: Risk of fire. Most dwellings built before 1985 have supply wire

rated at 60°C. Consult a qualified electrician before installation.

• To avoid hazards to children, account for all parts and properly dispose of

all packing materials.

• Call the Technical Support department at Con-Tech Lighting with any

installation questions: 847.559.5500.

White to White

Black to Black

Ground Wire

LVR316 INST

For Con-Tech Lighting Low Voltage Recessed Housing: LVR316

www.con-techlighting.com

All specifications subject to change without notice.

1-847-559-5500

This document can be recycled.

JOIST: 2" x 8"

3"

3"

INSULATION

CEILING MATERIAL

3"

Advertising