For Con-Tech Lighting Non-IC and IC 4” Envision Housings: RS4175 and RS4150-IC

www.con-techlighting.com

All specifications subject to change without notice.

1-847-559-5500

This document can be recycled.

Snap Hook

Safety

Cable

Angle Indicator

Lamp Bracket

Tab

Hot Aiming Feature

LAMPING/TRIMS:

Lamp bracket accommodates from 1 to 3 accessories.
Locking aiming on trim and locking rotation in housing ensures beam

alignment when relamping.
Connect lamp to socket by pressing lamp firmly into socket holes.
Install lamp into trim by placing under lamp bracket.
Connect safety cable on trim to fixture through hole in bracket

attached to inside top of housing. (Figure 5)
Align tab on trim with alignment notch on the 360° aiming ring in

housing.
Press firmly upwards on trim until ball fastener “clicks” into place.
RELAMPING:

Remove trim from ceiling, slide lamp out from under bracket, replace

lamp and reinstall trim by lining up alignment tab on trim with

alignment notch in housing to ensure correct beam placement.
HOT AIMING/POWER-ON AIMING:

Insert Phillips head screw driver through opening in trim (CST403 &

CST405).
Adjust lamp to desired position (up to 45°) by inserting screw driver

into screw and rotating.
Use aiming angle marks as a visual reference to aim multiple fixtures.
360° AIMING RING ADJUSTMENT:

With trim inserted into housing, rotate into position by turning trim up

to 360°
Carefully remove trim as to not change position.
Reach into housing and turn knob to lock into place. (Figure 5)
Replace trim into fixture, first align tab on trim with alignment notch

on aiming ring.
Press firmly upwards until ball fastener “clicks” into place.

IMPORTANT SAFETY INSTRUCTIONS:

• Read all the instructions before installation. Save instructions for

later use.

• Turn off power at fuse or circuit breaker box before installation or

before doing any maintenance work.

• Product must be grounded to avoid potential electric shock and any

other potential hazards.

• Product must be mounted in locations and at heights and in a

manner consistent with its intended use, and in compliance with

National Electrical Code and local codes. Use of accessory

equipment is not recommended.

• Installing contrary to instructions may cause unsafe conditions.

• Do not block light from the trim aperture, in whole or in part, as this

may cause unsafe conditions.

Warning: Risk of fire. Most dwellings built before 1985 have supply

wire rated at 60°C. Consult a qualified electrician before installation.

• To avoid hazards to children, account for all parts and properly

dispose of all packing materials.

• Call the Technical Support department at Con-Tech Lighting with any

installation questions: 847.559.5500.