ConTech Lighting RA6142HEMVR User Manual

Installation instructions

Advertising
background image

INSTALLATION INSTRUCTIONS

For 6" or 8" Horizontal Lamp Architectural Grade Compact Fluorescent Recessed Housings

RA6113HEMV, RA6118HEMV, RA6142HEMV, RA6213HEMV, RA6218HEMV, RA6226HEMV, RA8113HEMV,

RA8118HEMV, RA8142HEMV, RA8213HEMV, RA8218HEMV, RA8226HEMV, RA8242HEMV

www.con-techlighting.com

1-847-559-5500

RAHEMV INST

All specifications subject to change without notice.

IMPORTANT SAFETY INSTRUCTIONS:

• Read all the instructions before installation. Save instructions for later use.

• Turn off power at fuse or circuit breaker box before installation or before

doing any maintenance work.

• Product must be grounded to avoid potential electric shock and any other

potential hazards.

• Product must be mounted in locations and at heights and in a manner

consistent with its intended use, and in compliance with National Electrical

Code and local codes. Use of accessory equipment is not recommended.

• Installing contrary to instructions may cause unsafe conditions.

• Do not block light from the trim aperture, in whole or in part, as this may

cause unsafe conditions.

Warning: Risk of fire. Most dwellings built before 1985 have supply wire

rated at 60°C. Consult a qualified electrician before installation.

• To avoid hazards to children, account for all parts and properly dispose of

all packing materials.

• Call the Technical Support department at Con-Tech Lighting with any

installation questions: 847.559.5500.

INSTALLATION PROCEDURES

NON-IC FIXTURE:

Housing can NOT be installed in direct contact with insulation. Do not

install insulation within 3" of fixture sides or wiring compartment, nor above

fixture in such a manner to entrap heat. (Figure 1)

HANGER BARS:

Install hanger bars to fixture, ensure end tab is facing outward. (Figure 2)

Extend bar hangers to fit between joists and position fixture temporarily by

hammering nail on bars into the joists. Hangers should be level with bottom

of joists (Figure 3). Use T-Bar slot in the bottom bars for suspended (T-Bar)

ceilings, bending the tabs to hold T-Bar tightly.

ELECTRICAL CONNECTION:

Junction box contains two wires: a black (hot +) and a white (neutral -).

Wires must be spliced to the current feed wires. MAKE SURE TO SPLICE

WHITE TO WHITE AND BLACK TO BLACK. After splicing is completed, insert

wires carefully into junction box. Connect green ground wire to green

grounding pigtail in junction box (Figure 4). Replace cover.

GROUNDING:

For Romex or 3-wire BX, flexible metal cable installations attach supply

ground lead (green) to bare copper ground lead or ground screw in wiring

box mounted on plaster frame. Local electrical codes should be consulted

to determine acceptable installation: conduit, romex or flexible metal cable.

TRIM (ROUGH-IN) ASSEMBLIES:

Push trim into the trim ring and place through the hole on plaster frame.

Install the socket housing on the top of trim with screw and nut provided.

Push the trim in completely flush to the ceiling.

REPLACEMENT OF BALLAST:

If the ballast is not working properly, replace with the same ballast type.

(Figure 5) Remove nut in the trim and pull down trim. Pull off the junction box

cover installed ballast and remove ballast from the cover by unscrewing the

two screws. Install new ballast and wire to same colored wire connectors on

the back of the ballast according to the diagram on the ballast, then wire to

supply wires in the junction box. Replace trim as instructed above.
Use only those trims, lamps and maximum wattages proper for this fixture,

as indicated on the label within the housing. Do not exceed maximum

wattage lamp shown for each trim.
The National Electrical Code, Article 110-3(B), states that “Listed or labeled

equipment shall be used or installed in accordance with any instructions

included in the listing or labeling.” Use only with Con-Tech UL listed trims.

Use of other trims not listed in this fixture, including those that are UL

classified, is a violation of N.E.C. 110-3(B) and voids all warranties.

White to White

Black to Black

Ground Wire

JOIST: 2" x 8"

3"

3"

INSULATION

CEILING MATERIAL

Nail In Tabs

Bar Hanger

Joist

Screw

CFL Ballast

Junction Box

Socket Cup

Nut to Attach to

Socket Cup Screw

Trim

Trim Ring