ConTech Lighting SR2004 User Manual

ConTech Lighting For the car

Advertising
background image

INSTALLATION PROCEDURES

• Place fixtures so that they will not come in contact with flammable materials.

• Use only insulated staples or plastic ties to secure cords and 12V wiring.

• Route and secure cords and wiring so that can not be pinched or damaged.

• Cut a 1-1/4" diameter hole in surface (Fig. 1)

• Make all the appropriate electrical connections between the fixture and the

power source. (Fig. 2)

• Squeeze retention clips and feed clips and fixture into the hole. Fixture

should be held in place by the retention clips on fixture. (Fig. 3)

• Not suitable for covering with thermally insulating material.

ELECTRICAL CONNECTIONS

Fixture requirements: (1) 5W, 700mA LED
Driver requirements: 120V, DC Constant current 700mA – maximum load

of driver should match fixture layout requirements.

• Provide UL listed driver and enclosure for load required. (Verify with LED

driver manufacturer specifications for correct loads and wiring diagrams)

• Connect power supply to LED driver. (Fig. 2)

• Connect black to black (hot), white to white (neutral), and green to green

(ground) with twist type wire connectors (not provided) on primary side

• Secondary side provide Class II plenum rated wire (minimum 18-2) to

connect in series (red to black) for proper connections.

IMPORTANT SAFETY INSTRUCTIONS:

• Read all the instructions before installation. Save instructions for later use.

• Turn off power at fuse or circuit breaker box before installation or before

doing any maintenance work.

• Product must be grounded to avoid potential electric shock and any other

potential hazards.

• Product must be mounted in locations and at heights and in a manner

consistent with its intended use, and in compliance with National Electrical

Code and local codes. Use of accessory equipment is not recommended.

• Installing contrary to instructions may cause unsafe conditions.

• Do not block light from the trim aperture, in whole or in part, as this may

cause unsafe conditions.

Warning: Risk of fire. Most dwellings built before 1985 have supply wire

rated at 60°C. Consult a qualified electrician before installation.

• To avoid hazards to children, account for all parts and properly dispose of

all packing materials.

• Call the Technical Support department at Con-Tech Lighting with any

installation questions: 847.559.5500.

For Con-Tech Lighting sirius

®

PLUTON LED Accent Fixture: SR2004, SR2005

This document can be recycled.

SR2004 5 INST

www.con-techlighting.com

All specifications subject to change without notice.

1-847-559-5500

1-1/4"