INSTALLATION PROCEDURES

• It is recommended to layout the system before permanently installing the adhesive backed

LED tape.

• Ensure that the power supply is sized properly for LED tape loading otherwise power supply

or LED tape may be damaged. Example: the High Output Outdoor LED tape consumes

1.8Ws per foot. This means that a 36W power supply can effectively drive 20-feet of LED

tape (36 ÷ 1.8 = 20). Review the loading chart to determine power supply maximum load

run length capabilities.

• Locate position for power supply and install in accordance with the National Electrical Code

(NEC) and local codes. Review the loading chart to determine the maximum system run

length; Refer to wiring chart or power supply distance from first LED tape section to

minimize the effects of voltage drop.

A. PLUG-IN STYLE: Class 2, 120V input with 12V secondary. Install away from heat sources.

• The LED tape can be field cut at marked cut lines only, every 4". One cut per reel. Cutting

the tape terminates the conductivity of the tape.

• At the cut end, apply silicone sealant (provided) to the tape and cover with an end cap

(provided).

MOUNTING

• Clean mounting surface to ensure proper adhesion of LED tape.
• Measure the desired space for the LED tapelight installation; cut tape accordingly. Note that

the LED tape, adapter and infrared receiver (on the RGB tape) are pre-assembled. (Figure 1)

• Install the tapelight by either:

A. Carefully pressing the LED tape onto mounting surface. Do not apply excess pressure.

Avoid contact with LEDs. (Figure 2)

B. Place the LED tape into the desired position and use the mounting clips and screws

provided to secure into place. Recommended maximum distance between mounting clips

is 24" for most applications. (Figure 3)

• Do not pinch or bend LED tape and connectors at hard angles. Bend only between LEDs.

Use an angle greater or equal to 90° when there is an LED chip on the corner while placing

the tape in a concave position. Use an angle greater or equal to 60° when there is no LED

chip on the corner while placing the tape in a concave position. Use an angle greater or

equal to 60° when there is an LED chip on the corner while placing the ape in a convex

position. In the convex position, the angle should not reach 90°. (Figure 4)

RGB CONTROLLER

• Install the Infrared receiver (Figure 5). Either remove the protective tape from the adhesive

back of the infrared receiver, then place the infrared receiver into position and press to

ensure a proper adhesion to the surface; or use the two screws to install the infrared

receiver into desired position.

• When using the remote, the infrared receiver should face the remote. Sensor efficiency

distance ≤16.5 feet and sensor efficiency angle about 60°

POWER SUPPLY

• Connect adapter to power outlet
• WARNING: If using the adapter outdoors where it could be exposed to rain, snow, or solid

objects less than 1mm, to protect against electric shock, install the adapter only to a

receptacle that has a weatherproof enclosure.

• WARNING: Risk of electric shock. Mount the adapter at a height 12" or greater from the

ground surface.

• The LED strip and infrared receiver can be used outdoors but are not submersible.

IMPORTANT SAFETY INSTRUCTIONS:

• Read all the instructions before installation. Save instructions for later use.

• Turn off power at fuse or circuit breaker box before installation or before doing any maintenance work.

• Product must be grounded to avoid potential electric shock and any other potential hazards.

• Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in

compliance with National Electrical Code and local codes. Use of accessory equipment is not recommended.

• Installing contrary to instructions may cause unsafe conditions.

• Do not block light from the trim aperture, in whole or in part, as this may cause unsafe conditions.

Warning: Risk of fire. Most dwellings built before 1985 have supply wire rated at 60°C. Consult a qualified

electrician before installation.

• To avoid hazards to children, account for all parts and properly dispose of all packing materials.

• Call the Technical Support department at ConTech Lighting with any installation questions: 847.559.5500.

1. Distance from first LED tape section to end of LED tape run. Exceeding this length

may result in inconsistent light output from beginning to end of the LED tape run.

ConTech POWER SUPPLY

INPUT VOLTAGE: 12V DC

OUTDOOR

WATTS PER FOOT: 1.8

MODEL NO.

TYPE

WATTAGE

MAX LOAD

1

TLPO12VP36

Plug-In

36W

20 ft.

TLPO12VP60

Plug-In

60W

33 ft.

1

2
3
4

5

LED Chip

Correct

lncorrect

lncorrect

Angle 90

o

Angle 60

o

Adapter

Infrared receiver

60°

10'

10'

≤ 16.5'

Advertising