Host interface, Host controlle – ACTiSYS ACT-IR100SD User Manual

Page 8

Advertising
background image

The Wireless Connectivity Expert

ACT-IR100SD OBEX Server

User’s Manual

 Copyright 2000-2006 ACTiSYS Corp.

Page 8 of 17

Oct 30, 2006

4. HOST INTERFACE

The host interface of ACT-IR100SD is a full-duplex asynchronous RS232 DB9M connector. The following

table is the signals of DB9M connector. It can be treated as DTE. The data bytes are transmitted via TXD

pin and received via RXD. Each data byte consists of one start bit (0), 8 data bits (LSB first, MSB last), a

stop bit (1) and no parity bit.

Implementing H/W flow control signals in host end is recommended. Since ACT-IR100SD is a buffer

limited dongle. Without flow control will probably cause data loss sometimes. The H/W flow control

relative signals are: DTR, RTS, DSR and CTS, which are defined exactly as RS232 DTE interface.










1.1.1.1.2

ACT-I

R100

SD

Host

controlle

r

/RxD

/TXD

/TXD

/RXD





/CTS

/RTS

/DTR

/DSR

/RTS

/CTS

/DSR

/DTR







Data Frame

D0 D1 D2 D3 D4 D5 D6 D7

STOP

BIT

START

BIT

MSB

LSB

TxD / RxD

Marking

Version

1.0

Advertising