Installation Diagrams

DIAGRAM 7: JAMB CUTOUT DIMENSIONS

DIAGRAM 6: JAMB VIEW

3

DIAGRAM 5: FAIL SAFE CONVERSION

a. Loosen the two #2-56 screws located on the back of the

strike as shown above, but do not remove them.

b. Move screws to the fail safe position as shown above.

c. Tighten screws.

Convert Mode

d. Verify the strike is now in the Fail Safe operation

mode. If the strike still operates as Fail Secure, be

sure screws are fully seated in the bottom

position.

Verify

4-7/8” x 1-1/4” Square Corner Faceplate

ANSI Metal Jamb Installations

5200 with 501 Faceplate

3 -3/8"

[85.7]

1 -1/4"

[31.8]

4 -7/8"

[124]

13/16"

[20.6]

[2.3]

3/32"

[mm]

Inches

1 -1/4"

[31.8]

4 -7/8"

[124]

4 -1/8"

[104.8]

1 -7/16"

[36.6]

a

b

a. Slowly turn the horizontal adjustment screws to adjust the strike

in-frame. Do not remove the screws or completely rotate them

more than 3 full turns.

b. Once the strike has been adjusted, securely tighten the screws.

This will allow the K-nut’s teeth to dig into the strike housing to

prevent slippage during use.

K-NUT

a

b

DIAGRAM 6: HORIZONTAL ADJUSTMENT