Installation directions – HES 2005M3 SMART Pac III User Manual

Page 2

Advertising
background image

2

Installation Directions

1. Connecting the SMART Pac III: Connect the SMART Pac III to the wires coming from the

access control panel as shown on Page 3, using either the 12V or 24V pigtail provided with the

HES electric strike. If using other ASSA ABLOY electrified products, refer to the wiring schematic

on Page 4.

2. Using SMART Pac III to confirm correct input voltage: Set the SMART Pac’s slide switch to

the voltage of the power supply (see Page 3) and activate power. The behavior of the SMART

Pac’s LED Status Indicator will communicate the following:

 Voltage input, and if it is within the input requirements listed on Page 3

 Correct position of the the SMART Pac’s slide switch for the voltage input

3. Resolving Fault Codes: A blinking or unlit LED indicates corrective action is needed.

a. Using the LED STATUS INDICATOR TABLE below determine the appropriate

corrective action.

b. Remove power to the SMART Pac III and correct the error condition.

c. Wait 10 seconds and re-power the unit. This will reset the LED indicator.

Warning: The slide switch configures the wiring to the electric strike. It does not control the

SMART PAC III’s voltage output and will not prevent an overload condition if set improperly. The

voltage rating of the electric strike must match the voltage output of the power supply (e.g.: Use

a 24 Volt strike if you have a power supply rated at 24 Volts.)

If using an electric strike and/or additional devices in series with a single SMART PAC III, do not

exceed a current rating of 750 MA at 25 C.

4. Connecting the Electric Strike: With no power supplied to the SMART Pac III, connect the

electric strike. Verify the operation of the electric strike and a steady LED color when power is

present.

*See input requirements on Page 3

LED STATUS INDICATOR TABLE

NOTE: A self re-setting poly switch is built into the SMART Pac III to prevent damage to the

electric strike in an over-current situation or downstream short. Normally, the SMART Pac III will detect

over current situations and shut down the power output before the poly switch opens. If the poly switch

trips there will be no voltage output and no LED status.

LED COLOR

INPUT CONDITION

OUTPUT CONDITION

Steady Green

10.5-21V*

15 VDC MAX STEPPING TO 9 VDC

Steady Yellow

21-33V*

30 VDC MAX STEPPING TO 18 VDC

Blinking 2 Yellow/2Green

ANY

WRONG SLIDE SWITCH POSITION

Off or Blinking Green TOO LOW (min. 10.5V)

~ 0

Blinking Yellow

TOO HIGH (>33V)

~ 0

Blinking Yellow/Green

ANY

DOWNSTREAM SHORT

1
2

3
4
5
6

CORRECTIVE ACTION

NONE REQUIRED

NONE REQUIRED

CHANGE SLIDE SWITCH POSITION

INCREASE VOLTAGE

DECREASE VOLTAGE

FIND AND REMOVE SHORT

Advertising