29

29

INSTRUCTION

DEFINITION FOR SPECIFIC INSTRUCTION

NOTES

#

DESCRIPTION

INPUT

OUTPUT

2C

CONTROLS THE STATUS OF A

PORT

0–close
1–open

Output bit:

O0–O5 = output # or 0 for all outputs
O6–0 = Tx; 1 = Rx

1, 2, 4, 5

2D

READS THE STATUS OF A PORT

0–open

Output bit:

O0–O5 = output #
O6–0 = Tx; 1 = Rx

2, 3, 4, 5

All the values in the table above are hexadecimal, unless otherwise

stated


NOTES:

NOTE 1 – When the PC sends this command, if the instruction is valid the unit replies by sending the PC the same 4
bytes that it was sent (except for the first byte where the Destination bit is set high).

NOTE 2 – If O6 = 0 (Tx) – This command defines/reads the definition of the output # (1, 2 or3) to pass the RS-232/Direct
command from any input. In this case the instruction does not modify previously set output numbers, allowing the setting
of multiple outputs for the Direct command. If O6 = 1 (Rx), the command defines/reads the definition of the output # (1, 2
or 3) to pass the reply from the output to inputs. In this case, the instruction resets a previously set output number,
preventing the setting of multiple outputs for the reply.

NOTE 3 – The reply to this command is as follows: The same command and output codes as were sent are returned,
and the input is assigned the value of the parameter that was read. The reply is per the definitions in command 44.

NOTE 4 – At initial power-on or on reception of command 44 or 45, any received bytes are analyzed to see whether it is
a command 44 or 45. If not, it is transmitted to the output based on the existing setup. If the analyzed bytes are a
command 44 or 45, the unit waits for the other 3 bytes and interprets them as a Protocol 2000 command. The command
is executed if relevant to this machine number or discarded if not.

NOTE 5 – This command works only when the unit is configured for Software mode.

Sample TP-410 Control Commands

Command

Description

Reply

2C 80 80 81

Close all output ports for direct command

6C 80 80 81

2C 80 C0 81

Close all output ports for reply command

6C 80 C0 81

2C 81 82 81

Open port 2 for direct command

6C 81 82 81

2C 81 C1 81

Open port 1 for reply command

6C 81 C1 81

2D 80 81 81

Check status of port 1 for direct command. Port is closed

6D 80 81 81

2D 80 82 81

Check status of port 2 for direct command. Port is open

6D 81 82 81

2D 80 C1 81

Check status of port 1 for reply command. Port is open

6D 81 C1 81

2D 80 C2 81

Check status of port 2 for reply command. Port is closed

6D 80 C2 81

All the values in the table above are hexadecimal, unless otherwise

stated