Kramer VP-727A-BA Protocol (Ver. 3.21)

23

9 Kramer VP-727A-BA Protocol (Ver. 3.21)

A protocol for the VP-727A-BA is described below.

For RS-232: A null-modem connection between the PC and the VP-727A-BA

is required, and data is at 9600 baud (for standalone

1

For RS-485: A differential (2 wire) connection between the VP-727(xl) and the

VP-727A-BA is required (A, B); GND may be connected to the shield if

required.

), no parity, 8 data bits, and

1 stop bit.

All values shown are hexadecimal.

Table 4: Instruction Codes for the VP-727A-BA Protocol

INSTRUCTION

1

st

Byte

2

nd

Byte

3

rd

Byte

4

th

Byte COMMENT

FACTORY RESET

00

81

81

81

See NOTE 1

RESET

00

80

80

81

INPUT 1 → PROGRAM OUT

02

81

81

81

INPUT 2 → PROGRAM OUT

02

82

81

81

INPUT 3 → PROGRAM OUT

02

83

81

81

Select

INPUT 4 → PROGRAM OUT

02

84

81

81

Input

INPUT 5 → PROGRAM OUT

02

85

81

81

for

INPUT 6 → PROGRAM OUT

02

86

81

81

Program

INPUT 7 → PROGRAM OUT

02

87

81

81

INPUT 8 → PROGRAM OUT

02

88

81

81

See NOTE 1

READ PROGRAM INPUT #

06

81

80

81

See NOTE 3

INPUT 1 → PREVIEW OUT

02

81

82

81

INPUT 2 → PREVIEW OUT

02

82

82

81

INPUT 3 → PREVIEW OUT

02

83

82

81

Select

INPUT 4 → PREVIEW OUT

02

84

82

81

Input

INPUT 5 → PREVIEW OUT

02

85

82

81

For

INPUT 6 → PREVIEW OUT

02

86

82

81

Preview

INPUT 7 → PREVIEW OUT

02

87

82

81

INPUT 8 → PREVIEW OUT

02

88

82

81

See NOTE 1

READ PREVIEW INPUT #

06

82

80

81

See NOTE 3

1 38,400 baud when operating with the VP-727xl and 115,200 baud when operating with the VP-727