Connecting the VS-169TP 16x9 CAT 5 Matrix Switcher

15

15

6.1 Connecting the RS-232 Ports

The VS-169TP includes the following RS-232 ports:

Two local RS-232 IN ports and one local RS-232 OUT port (see

Section

6.1.1

RS-232 IN and RS-232 OUT control ports (see

) to transmit RS-232 signals along with the video and audio signals

from the source to the destination units

Section 6.1.2

6.1.1 Connect the Local RS-232 Ports

) to control

the matrix itself (same functions as the RS-485 and IP interfaces)

To connect a PC or controller to the local ports, connect the 9-pin D-sub ports

of the PC or controller to the LOCAL IN RS-232 IN 1 and/or RS-232 IN 2

ports, and to the LOCAL RS-232 OUT port of the VS-169TP unit (via

RS-232 cables), as required.

6.1.2 Connect the Control RS-232 Ports

To connect a PC to the VS-169TP unit:
1. Connect the RS-232 9-pin D-sub port on your PC to the CONTROL

RS-232 IN 9-pin D-sub rear panel port of the VS-169TP with a 9-wire

cable

1

2. Make sure that DIP 7 is set to ON

.

2

6.2 Setting the DIP-switches

.

Figure

and

5

Table

define the VS-169TP DIP-switches. By default the

VS-169TP (when used as a single unit) is set to Machine #1 (see

4

Table

).

When connecting more than one VS-169TP unit, allocate a unique Machine #

to the VS-169TP. The line termination DIP-switch is for use only with the

RS-485 port.

5

Machine Number

RS-232 Termination

Figure 5: DIP-switch Settings

Table 4: DIP-switch Settings

DIPS

Description

1, 2, 3, 4

Set the MACHINE # (see

Section 6.2.1

)

5, 6

Not used

7

Set ON to avoid having to connect a null-modem

adapter or using a null-modem connection

8

Set ON for RS-485 termination for the first and the

last machine (RS-485 line terminates with 110Ω);

for others set OFF (RS-485 line is open)

1 The cable should consist of at least three straight-through wires: PINs 2, 3 and 5