12 kramer protocol 2000, Kramer protocol 2000, Table 5: protocol definitions – Kramer Electronics VS-84H User Manual

Page 23

Advertising
background image

Kramer Protocol 2000

KRAMER: SIMPLE CREATIVE TECHNOLOGY

20

12 Kramer Protocol 2000

The VS-84H is compatible with Kramer’s Protocol 2000

1

(version 0.50).

This RS-232/RS-485 communication protocol uses four bytes of

information as defined below.

Table 5: Protocol Definitions

MSB

LSB

DESTI-

NATION

INSTRUCTION

0

D

N5

N4

N3

N2

N1

N0

7

6

5

4

3

2

1

0

1st byte

INPUT

1

I6

I5

I4

I3

I2

I1

I0

7

6

5

4

3

2

1

0

2nd byte

OUTPUT

1

O6

O5

O4

O3

O2

O1

O0

7

6

5

4

3

2

1

0

3rd byte

MACHINE NUMBER

1

OVR

X

M4

M3

M2

M1

M0

7

6

5

4

3

2

1

0

4th byte

1

st

BYTE: Bit 7 – Defined as 0.

D – “DESTINATION”: 0 - for sending information to the switchers (from the PC);

1 - for sending to the PC (from the switcher).

N5…N0 – “INSTRUCTION”

The function that is to be performed by the switcher(s) is defined by the INSTRUCTION (6 bits). Similarly, if a function is

performed via the machine’s keyboard, then these bits are set with the INSTRUCTION NO., which was performed. The

instruction codes are defined according to the table below (INSTRUCTION NO. is the value to be set for N5…N0).

2

nd

BYTE:

Bit 7 – Defined as 1.

I6…I0 – “INPUT”.

When switching (ie. instruction codes 1 and 2), the INPUT (7 bits) is set as the input number which is to be switched.

Similarly, if switching is done via the machine’s front-panel, then these bits are set with the INPUT NUMBER which was

switched. For other operations, these bits are defined according to the table.

3

rd

BYTE:

Bit 7 – Defined as 1.

O6…O0 – “OUTPUT”.

When switching (ie. instruction codes 1 and 2), the OUTPUT (7 bits) is set as the output number which is to be switched.

Similarly, if switching is done via the machine’s front-panel, then these bits are set with the OUTPUT NUMBER which was

switched. For other operations, these bits are defined according to the table.

4

th

BYTE: Bit 7 – Defined as 1.

Bit 5 – Don’t care.

OVR – Machine number override.

M4…M0 – MACHINE NUMBER.

Used to address machines in a system via their machine numbers. When several machines are controlled from a single serial

port, they are usually configured together with each machine having an individual machine number. If the OVR bit is set, then

all machine numbers will accept (implement) the command, and the addressed machine will reply.

1 The instruction codes in

Table 6

are a sub-set of the Protocol 2000. The full protocol is available from

http://www.kramerelectronics.com