Kramer Electronics RC-3TBU User Manual

Page 11

Advertising
background image

8

SL-14RC/N - Defining the Remote Control Panels

#

Feature

Function

5

8 Position Rotary
Switch

For assigning which buttons on the SL-14RC/N are
emulated by the buttons on the RC-3TB

6

K-NET Termination
Switch

Terminates the K-NET to RC-3TB daisy-chain

7

K-NET Connector

Connects to either SL-14RC/N or additional RC-3TB

8

Front Panel

For mounting the RC-3TB

9

Printed Circuit Board

Contains the components of the RC-3TB

When configuring the SL-14RC/N with K-Config (version 1.0.1.X and up), you can

choose to use the K-Net port for connecting K-Net compatible user interfaces (for

example, RC-62/RC-63/RC-53 series) or to connect to the RC-3TB.

If there is no K-Net auxiliary device specified in the K-Config control room tree,

the K-Net port of the SL-14RC/N will be configured to connect to an RC-3TB/U.

When using the RC-3TB, button 1 is always assigned to the second DISPLAY

button (button number 12) on the SL-14RC/N. The position of the rotary switch (in

the following table) determines which of the 12 buttons on the SL-14RC/N are

emulated by buttons 2 and 3 on the RC-3TB.

Rotary Switch

Position

Button 1

Button 2

Button 3

0

12

7

8

1

12

7

9

2

12

7

10

3

12

8

9

4

12

8

10

5

12

9

10

6

12

7

9

7

Service use only

For example, if the rotary switch is in position 4, the 3 buttons on the RC-3TB will

duplicate the functions of buttons 12, 8, and 10 on the SL-14RC/N. That is, in this

example, pressing button 1 on the RC-3TB has the same effect as pressing button

12 on the SL-14RC/N, pressing button 2 on the RC-3TB has the same effect as

pressing button 8 on the SL-14RC/N, and pressing button 3 on the RC-3TB has

the same effect as pressing button 10 on the SL-14RC/N.