Figure 4: rc-53dlc european version– rear panel, Defining the rc-53dlc – Kramer Electronics RC-53DLC User Manual

Page 10

Advertising
background image

Defining the RC-53DLC

7

7

Figure 2

and

Table 2

define the RC-53DLC rear panel for the European version.

Figure 4: RC-53DLC European Version– Rear Panel

Table 4: RC-53DLC European Version – Rear Panel Features

#

Feature

Function

1

Program USB Connector

Connect to a computer for firmware upgrade

1

2

Grounding Screw

Connect to grounding wire (see

Section

4.3

)

3

RS-232 Terminal Block

For factory use only

4

K-NET Terminal Block

Connect the GND to the Ground connection

2

, connect B (-) and A (+)

to RS-485, and connect +12V to +12V on the companion unit

5

K-NET Terminal Block

6

PROG Switch

For technical support use only (should be set to the right in the direction of

the arrow for normal operation)

7

K-NET TERM Switch

Slide downwards (in the direction of the arrow) for K-NET termination, slide

upwards to leave bus unterminated. The last physical device on a K-NET
bus must be terminated

You can reach the KNET termination switch by inserting a small screwdriver
into the gap between the rear panel PCB and the metal rear panel cover.












1 When the unit is connected via K-NET to a Master Room Controller, you can upgrade the firmware via the USB or ETH ports of the

Master Room Controller

2 The ground connection is sometimes connected to the shield of the RS-485 cable (in most applications, it is not connected)