1 connecting rs-232 devices, 2 connecting the k-net port, 3 grounding the rc-63dln – Kramer Electronics RC-63DLN User Manual

Page 14: Connecting rs-232 devices, Connecting the k-net port, Grounding the rc-63dln, Figure 6: k-net pinout connection, Figure 7: grounding connection components

Advertising
background image

RC-63DLN

Connecting the RC-63DLN Room Controller

11

4.1

Connecting RS-232 Devices

You can control an AV device such as a projector by connecting them to the

RC-63DLN via their RS-232 connection.

To connect a device to the RC-63DLN via RS-232:

Using a straight cable, connect pin 2 to TX, pin 3 to RX and pin 5 to GND on

the RS-232 terminal block connector of the RC-63DLN

4.2

Connecting the K-NET Port

The K-NET port is wired as shown in

Figure 6

.

Figure 6: K-NET PINOUT Connection

If your device is the first or last device on the line, slide the K-Net termination switch

up otherwise make sure it is set to down (see

Section

3.2

).

4.3

Grounding the RC-63DLN

The grounding screw is used to earth the chassis of the unit to the building ground

preventing static electricity from impacting the performance of the unit.

Figure 7

defines the grounding screw components.

Figure 7: Grounding Connection Components


#

Component Description

1

M3X6 screw

2

1/8" Toothed Lock Washer

3

M3 Ring Tongue Terminal

Advertising