Kramer Electronics SL-10 User Manual

Page 9

Advertising
background image

6

SL-10 - Overview

#

Feature

Function

8

K-NET Connector

PIN GND is for the Ground connection; PIN B (-) and
PIN A (+) are for RS-485, and PIN +12V is for
powering other units

K-NET is a proprietary Kramer protocol for
interconnecting Kramer units

The ground connection is sometimes connected to the
shield of the RS-485 cable (in most applications, it is not
connected)

Note that the SL-10 cannot receive power via the K-NET
connector, but can power other units (but not another
SL-10)

9

RS-485 TERM Switch

Slides down for RS-485 termination, slides up for not
terminated

10

K-NET TERM Switch

Slides down for K-NET termination, slides up for not
terminated

11

PROG. Switch

For service use only

12

12V DC Socket

12V DC connector for powering the unit

13

IR
INPUTS

Built-in receiver and
STATUS LED

Accepts IR remote commands

14

3.5mm Mini Jack

Connects to an external IR receiver

15

RELAY LEDs

Illuminate when a relay is active (1 to 5)

16

IR LEDs

Illuminate when an IR port is active

17

NET LED

Illuminates when The Ethernet link is active

18

K-NET LED

Illuminates while transmitting over K-NET

19

RS-485 LED

Illuminates while transmitting/receiving on an RS-485
port

20

RS-232 (Tx/Rx) LEDs

Illuminate while transmitting/receiving on an RS-232
port (1 to 2)

21

GPI/O LEDS

Illuminate while transmitting/receiving on a general
purpose I/O port (1 to 2)

22

PROGRAM USB Connector

Connect to a computer for unit configuration and
firmware upgrading

Advertising