4 comm settings sub-menu, 5 system sub-menu, Section – Kramer Electronics FC-340 User Manual

Page 19

Advertising
background image

16

FC-340 - Operating the FC-340

7.2.4

Comm Settings Sub-menu

The parameters in the Comm Settings sub-menu set the network IP and display

the serial communications values.

Parameter

Description

Options

NETWORK

IP address

Sets the IP network address

Any valid IP address
Default

—192.168.001.039

IP mask

Sets the IP network mask

Any valid subnet
Default

—255.255.000.000

IP gateway

Sets the IP gateway address Any valid gateway address

Default

—000.000.000.000

IP port

Sets the IP port number

Any valid TCP port
Default

—05000

RS-232

Baud

Displays the baud rate

115200

Parity

Displays the parity bit setting none

7.2.5

System Sub-menu

The parameters in the System sub-menu display the device versions and set the

LCD display characteristics.

Parameter

Description

FIRMWARE

The device firmware version

FPGA VER

The device FPGA version

S/N

The device serial number

7.3

Resetting the Device to Factory Default Configuration

To reset the device to the factory default configuration:

1. Turn the device off.

2. Press and hold the Reset button on the rear panel of the device.

3. While holding the button depressed, turn the device on.

4. Hold the button depressed for 10 seconds and release the button.

The configuration is reset to the factory default.