background image

Programming

124

MVP-5100/5150 Modero Viewpoint Touch Panels

"^" Button Commands (Cont.)

^FON

Set a font to a
specific Font ID
value for those
buttons with a
defined address
range.

Font ID numbers are generated by the TPDesign4 programmers report.
Syntax:

"'^FON-<vt addr range>,<button states range>,<font value>'"

Variable:

variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons

1 = Off state and 2 = On state).
font value = range = 1 - XXX. Refer to the Default Font Styles and ID Numbers section
on page 107
.

Example:

SEND_COMMAND Panel,"'^FON-500.504&510.515,1&2,4'"

Sets the font size to font ID #4 for the On and Off states of buttons with the variable text
range of 500-504 & 510-515.

The Font ID is generated by TPD4 and is located in TPD4 through the Main menu.
Panel > Generate Programmer's Report >Text Only Format >Readme.txt.

"^" Button Commands (Cont.)

^GDI

Change the

bargraph drag
increment.

Syntax:

"'^GDI-<vt addr range>,<bargraph drag increment>'"

Variable:

variable text address range = 1 - 4000.
bargraph drag increment = The default drag increment is 256.

Example:

SEND_COMMAND Panel,"'^GDI-7,128'"

Sets the bargraph with variable text 7 to a drag increment of 128.

^GIV

Invert the joystick
axis to move the
origin to another
corner.

Parameters 1,2, and 3 will cause a bargraph or slider to be inverted regardless of

orientation. Their effect will be as described for joysticks.
Syntax:

"'^GIV-<vt addr range>,<joystick axis to invert>'"

Variable:

variable text address range = 1 - 4000.
joystick axis to invert = 0 - 3.

For a bargraph 1 = Invert, 0 = Non Invert
Example:

SEND_COMMAND Panel,"'^GIV-500,3'"

Inverts the joystick axis origin to the bottom right corner.

0

2

3

1

1 = Invert horizontal axis

2 = Invert vertical axis
3 = Invert both axis locations