3 capturing the edid, 4 loading the default edid, Capturing the edid – Kramer Electronics WP-110 User Manual
Page 9: Loading the default edid
Advertising
6
PT-110xl, WP-110, PT-120xl, TP-120 - PT-110xl UXGA Line Transmitter
3.3
Capturing the EDID
To capture an EDID:
Connect the device from which you want to capture the EDID (for example, a
display, switcher, DA, etc.) directly to the UXGA input of the PT-110xl
Press the EDID capture button.
The EDID status LED flashes slowly several times. The new EDID is
captured when the LED stops flashing and lights solid.
Note: If the status LED flashes quickly for a few seconds and then stays on
solid, the PT-110xl could not capture the EDID and loaded the default EDID
instead.
3.4
Loading the Default EDID
To load the default EDID:
Press the EDID capture button.
The EDID status LED flashes quickly for a few seconds and then stays on
solid.
Advertising