6

PT-110xl, WP-110, PT-120xl, TP-120 - PT-110xl UXGA Line Transmitter

3.3

Capturing the EDID

To capture an EDID:

Connect the device from which you want to capture the EDID (for example, a

display, switcher, DA, etc.) directly to the UXGA input of the PT-110xl

Press the EDID capture button.

The EDID status LED flashes slowly several times. The new EDID is

captured when the LED stops flashing and lights solid.

Note: If the status LED flashes quickly for a few seconds and then stays on

solid, the PT-110xl could not capture the EDID and loaded the default EDID

instead.

3.4

Loading the Default EDID

To load the default EDID:

Press the EDID capture button.

The EDID status LED flashes quickly for a few seconds and then stays on

solid.