Step 1. Determine location for CAS Wall

Thimble. The CAS Wall Thimble should be

located near the stove to keep the connector

pipe to a reasonable length.

Step 2. Install CAS Wall Thimble. Cut and

frame an opening in the wall for the CAS

Wall Thimble. Refer to Table 1 for framing

dimensions. Install the black-painted inside

portion of the CAS Wall Thimble into the

framed opening. Secure the CAS Wall Thimble

with (4) 1-1/2” wood screws through the holes

on the face of the Thimble. Install the outside

portion of the CAS Wall Thimble by sliding

the radiation tube into the tube of the inside

portion of the Wall Thimble (Fig 11). Important:

the Wall Thimble must have a continuous tube

through the wall for a safe installation. The

CAS Wall Thimble can accommodate walls

up to 12” thick. If the wall is too thick for the

two halves of the CAS Wall Thimble to reach

each other, a field-fabricated tube of 26-gauge

galvanized steel (or better) must be made to

bridge the gap between the two halves. Slide

the field-fabricated tube over the inner portion

of the Wall Thimble and then slide the outer

portion of the Wall Thimble into the field-

fabricated tube to complete the continuous

tube through the wall. Make sure the air-inlet

openings of the Wall Thimble’s outside portion

are facing downward. Secure the outside

portion of the Wall Thimble to the wall with (4)

2-1/2” wood screws. Seal the perimeter of the

CAS Wall Thimble where it meets the wall with

a non-hardening sealant to provide a weather-

resistant seal.
Step 3. Connect CAS Connector Pipe. Refer

to Step 3 of the Vertical Installation. Use 45- or

90-degree elbows as needed.
Step 4. Connect to air inlet of stove. Refer to

Step 4 of the Vertical Installation.

Step 5. Install the chimney branch through the

wall. A horizontal section of chimney is needed

to go through the wall and twist lock into the

CAS Wall Thimble. Depending on your wall

thickness, use a section of chimney that will

reach from the Wall Thimble to the outside.

Connect the chimney Tee to the horizontal

chimney section (Fig 11). Support the chimney

TWIST LOCK CHIMNEY TEE

ONTO CHIMNEY BRANCH

AND ENSURE IT IS LEVEL

AND FACING UPWARDS.

USE ADDITIONAL SCREWS

IF NEEDED TO SECURE

CONNECTION.

TWIST LOCK SHORT

CHIMNEY SECTION

INTO WALL THIMBLE.

ATTACH INSIDE

PORTION OF WALL

THIMBLE WITH (4)

1-1/2" SCREWS.

THE TWO HALVES OF THE WALL THIMBLE

MUST OVERLAP. ATTACH OUTSIDE PORTION

OF WALL THIMBLE WITH (4) 1-1/2" SCREWS.

Figure 11