6. Commissioning, operation

6. Commissioning, operation

WARNING!

Prior to commissioning, the pressure transmitter must be subjected to a visual inspection.

Only use the pressure transmitter if it is in perfect condition with respect to safety.

6.1 Making the mechanical connection

The sealing faces at the instrument have to be undamaged and

clean.

When screwing the instrument in, the force required to do this must

not be applied through the casing, but only through the spanner flats

provided for this purpose and using a suitable tool.

The correct torque depends on the dimensions of the process

connection and the gasket used (form/material).

Maximum tightening torque

Process connection

Tightening torque

G ½ A DIN 3852-E

60 Nm

M14 x 1.5

60 Nm

7/16-10 UNF-2A

20 Nm

¼ NPT

34 Nm

When screwing in, do not cross the threads.

For information on tapped holes and welding sockets, see Technical information IN 00.14 at

www.wika.com.