Specifications

Model S-10, S-11

Power supply U+

U

B

in VDC

10 < U+

≤ 30 (14 … 30 with signal output 0 … 10 V)

Signal output and

R

A

in Ohm

4 … 20 mA, 2-wire

R

A

≤ (U+ – 10 V) / 0.02 A

maximum ohmic load R

A

0 … 20 mA, 3-wire

R

A

≤ (U+ – 3 V) / 0.02 A

0 … 5 V, 3-wire

R

A

> 5000

0 … 10 V, 3-wire

R

A

> 10000

{Other signal output on request}

Adjustability zero/span

%

±

5 using potentiometers inside the instrument

Response time (10 ... 90 %)

ms

1 (

≤ 10 ms at medium temperatures below<-30 °C (-22°F) for pres-

sure ranges up to 25 bar / 300 psi or with flush diaphragm (S-11).

Insulation voltage

VDC

500

5)

5)

Use NEC Class 02 power supply (low voltage and low current max. 100 VA even

under fault conditions)

Accuracy

% of span

0.25 {0.125}

6)

(BFSL)

0.5

7)

{0.25}

6) 7)

6)

Accuracy { } for pressure ranges

≥ 0.25 bar (100 INWC).

7)

Including non-linearity, hysteresis, zero point and full scale error (corresponds to

error of measurement per IEC 61298-2).
Adjusted in vertical mounting position with lower pressure connection.

Non-linearity

% of span

0.2 (BFSL) according to IEC 61298-2

Non-repeatability

% of span

0.1

according to IEC 61298-2

1-year stability

% of span

0.2 (at reference conditions)

Permissible temperature of

Medium

-30 ... +100 °C

-22 ... +212 °F

{-40 ... +125 °C}

{-40 ... +257 °F}

S-11 with cooling element

»

{-20 ... +150 °C}

{-4 ... +302 °F}

Ambience

-20 ... +80 °C

-4 ... +176 °F

S-11 with cooling element

»

-20 ... +80 °C

-4 ... +176 °F

Specifications

Model S-10, S-11

Storage

-40 ... +100 °C

-40 ... +212 °F

S-11 with cooling element

»

-20 ... +100 °C

-4 ... +212 °F

Rated temperature range

0 ... +80 °C

32 ... +176 °F

Temperature coefficients within

rated temperature range

Mean TC of zero

% of span

0.2 / 10 K (

< 0.4 for pressure range

0.25 bar (100 INWC))

Mean TC of range

% of span

0.2 / 10 K

CE- conformitiy

Pressure equipment directive

97/23/EC

EMC directive

2004/108/EC, EN 61 326 Emission (Group 1, Class B) and Immunity

(industrial locations)

Shock resistance

g

1000 according to IEC 60068-2-27 (mechanical shock)

Vibration resistance

g

20 according to IEC 60068-2-6 (vibration under resonance)

Wiring protection

Short-circuit proofness

S+ towards U-

Reverse polarity protection

U+ towards U-

Weight

kg

Approx. 0.2 (approx. 0.4 lb)

Approx. 0.3 with option accuracy 0.25% of span due to longer case