WIKA 233.50 User Manual

WIKA Measuring instruments

Advertising
background image

WIKA Alexander Wiegand SE & Co. KG

Alexander-Wiegand-Straße 30

63911 Klingenberg • Germany

Tel.

(+49) 9372/132-0

Fax

(+49) 9372/132-406

E-Mail [email protected]

www.wika.de

2094366.05 01/2011 GB/D

Installation with

spanner

Contents

1. Safety
2. Description
3. Specifications and intended use
4. Commissioning
5. Maintenance and cleaning
Appendix 1: Declaration of conformity
for models 23x.50/53.063 and 23x.30.063

Operating
instructions

1. Safety

WARNING!

Before installation, commissioning and operation, ensure that the appropriate

pressure gauge has been selected in terms of measuring range, design and

specific measuring conditions.

„

The compatibility of the materials under pressure with the medium must be checked!

„

In order to guarantee the measuring accuracy and long-term stability specified, the

corresponding load limits must be observed.

„

Serious injuries and/or damage can occur should these not be observed.

„

Only qualified persons authorised by the plant manager are permitted to install,

maintain and service the pressure gauges.

2. Description

„

Nominal size 63 mm

„

The gauges measure the pressure by means of resilient bourdon tube pressure

elements

„

The measuring characteristics are in accordance with EN 837-1 standard

„

In addition, the enclosing and the pressurised components of models 23x.30 also meet

the requirements of this standard, relating to safety pressure gauges with a solid baffle

wall (code S3).

3. Specifications and intended use

Pressure limitation
Model 23x.50/53:

Model 23x.30:

Steady:

3/4 × full scale value

Steady:

full scale value

Fluctuating: 2/3 × full scale value

Fluctuating: 0.9 × full scale value

Short time:

full scale value

Short time: 1.1 × full scale value

Mechanical connection
In accordance with the general technical regulations for pressure gauges (i.e. EN 837-2

"Selection and installation recommendations for pressure gauges").

When screwing gauges in, the force

required for this must not be applied

through the case, but rather through the

spanner flats (using a suitable tool) provi-

ded for this purpose on the square shaft of

standard connections.

Pressure gauge model 2 NS 63
per directive 94/9/EC (ATEX)

GB

II 2 GD c TX

Declarations of conformity see www.wika.de.
Specifications: see data sheet on www.wika.de
Subject to technical modifications.
© 2010 WIKA Alexander Wiegand SE & Co. KG

Advertising
This manual is related to the following products: