Specifications – WIKA TFS35 User Manual

Page 8

Advertising
background image

8

GB

11610115.03 11/2012 GB/D/F/E

WIKA operating instructions model TFS35

3. Specifications

„

Reset Switching Temperature (RST)

The reset switching temperature in bimetal temperature switches is typically 15 ... 30 K

below the switching temperature.

To ensure a safe reset of the switch at low switching temperatures, care must be

taken that the temperature difference between the measuring point and ambient is

high enough; since otherwise the switch cannot cool back down to the reset switching

temperature and thus the equipment will not be able to return to its normal state.

„

Ambient temperature

-50 ... +125 °C
Note:

With small insertion lengths there is a possibility that the temperature at the connector

can reach impermissibly high values. This absolutely must be taken into account in the

design of the measuring point.

Vibration resistance

Depending on the mounting situation, the medium, temperature and insertion length, the

vibration resistance is up to 10 g.

Shock resistance

Up to 100 g, depending on the mounting situation, medium and temperature

Working pressure

max. 100 bar, depending on the medium, temperature and thermowell design

Max. switching voltage

Resistive load (cos ϕ = 1):

„

AC 48 V, 3 A

„

DC 24 V, 3 A

„

DC 12 V, 4 A

Contact resistance

< 50 mΩ

Dielectric strength

AC 1,500 V, 50 Hz

between electrical connections and housing

Electrical connection

„

Rectangular connector per DIN EN 175301-803, Form A (replacement for DIN 43650)

„

Connector AMP Junior Power Timer, contacts gold-plated

„

FASTON blade terminals 6.3 x 0.8 mm

Other connections on request.

Advertising