Specifications – WIKA OLS-C20 User Manual

Page 8

Advertising
background image

8

WIKA operating instructions mini limit switch, model LSO.02

13334591.02 10/2010 GB/D/F/E

GB

3. Specifications

3. Specifications

General Data

Measuring accuracy

±0.5 mm

Ambient light

max. 10,000 Lux (immersed)

Mounting position

any

Weight

0.15 kg

Design Data

Medium temperature

-30 ... +140 °C

Ambient temperature

-25 ... +70 °C

Working pressure

0 ... 5 MPa (0 ... 50 bar)

Measuring length

see drawing on page 9

Process connection

G ½ A, M16 x 1.5, ½ NPT etc. see drawing on page 9

Materials

Sensor

Tip

Electronics housing

Stainless steel 1.4571

Quartz

Stainless steel 1.4301

Electrical Data

Supply voltage

DC 24 V -25 ... +30 %

Supply current max.

40 mA

Power consumption

1 W

Output

Voltage

Current

other

DC 24 V

0.5 A at Tu 70 °C

short-circuit protection, reverse voltage protection,

current, voltage and power limitation

Switching current

(Tu = 70 °C)

0.5 A

Electrical connection

PVC cable 3 x 0.14 mm²

Plug 4-pole series 713, M12

Ingress protection

With plug

With cable

IP 65 per EN 60 529

IP 66 per EN 60 529

For further specifications see WIKA data sheet LM 31.01 and order documentation.