8. Faults

Display

Meaning

Measures

Err.1

Measured value above allowable

range

Check: Is the pressure outside the

sensor‘s range? -> measured value

too high!

Sensor faulty

Return to manufacturer for repair

Err.2

Measured value below allowable

range

Check: Is the pressure outside the

sensor‘s range? -> measured value

too low!

Sensor defective

Return to manufacturer for repair

Err.3

Display range exceeded

Check: value above 9999 -> too high

to be displayed!

Err.4

Display range underflow

Check: value below ‚-2000‘ (Tare?)

-> too low!

Err.7

System error

Return to manufacturer for repair

Err.11

Value could not be calculated

Choose different unit

Calculation range exceeded

Choose different unit

WARNING!

If faults cannot be eliminated by means of the measures listed above,

the instrument must be shut down immediately, and it must be ensured

that pressure and/or signal are no longer present, and it must be

prevented from being inadvertently put back into service.

In this case, contact the manufacturer.

If a return is needed, please follow the instructions given in chapter “9.2

Return”.