INTRODUCTION

Model 05501LM Wind Monitor IS is an intrinsically safe wind sensor

that converts horizontal wind speed and direction measurements to

calibrated 4-20 mA signals. Each signal is derived from independent

2-wire loop-powered circuits. The sensor operates over a wide

ambient temperature range.

Intrinsic safety is achieved when the sensor is used with approved

barriers. Intrinsically safe systems are recognized as practical

and effective means of operating instruments in an explosive

environment. The technique limits the amount of energy available to

ignite explosive gases or ignitable mixtures. This is accomplished by

controlling the amount of voltage and current in the hazardous area.

When used with an approved Intrinsically Safe barrier, the Wind

Monitor IS can be used in Class 1, Division 1, Group A,B,C,D

hazardous areas. The categories are defined as follows:

Class I

Locations in which flammable gases or vapors are or may

be present in quantities sufficient to produce explosive or

ignitable mixtures.

Division 1 Locations in which hazardous concentrations in the air

exist continuously, intermittently, or periodically under

normal operating conditions.

Group A

Atmospheres containing acetylene

Group B Atmospheres containing hydrogen, or gases or vapors of

equivalent hazard, such as manufactured gas.

Group C Atmospheres containing ethyl-ether vapors, ethylene, or

cyclo-propane

Group D Atmospheres containing gasoline, hexane, naptha,

benzine, butane, propane, alcohol, acetone, benzol,

lacquer solvent vapors, or natural gas.

The Wind Monitor IS is rugged and corrosion resistant, yet accurate

and lightweight. Housing, nose cone, propeller, and other components

are injection molded with U.V. stabilized plastic. Both the propeller

and vertical shafts use stainless steel precision grade ball bearings.

Propeller rotation produces an AC sine wave signal with frequency

proportional to wind speed. Internal circuitry converts this signal to a

calibrated 4 to 20 mA current output.

Vane position is sensed by a 10K ohm precision conductive plastic

potentiometer. This signal is also converted to 4 to 20mA output.

The instrument mounts directly on a standard one inch pipe, outside

diameter 34 mm (1.34"). An orientation ring is provided so the

instrument can be removed for maintenance and re-installed without

loss of wind direction reference. Both sensor and orientation ring

are secured to the mounting pipe by stainless steel band clamps.

Electrical connections are made in a junction box at the base.

INITIAL CHECK-OUT

When the instrument is unpacked, check it carefully for signs of

shipping damage.

WIND SPEED SPECIFICATION SUMMARY

Operating Range

0 to 60 m/s (134 mph)

Gust Survival

100 m/s (220 mph)

Sensor Type

18 cm diameter 4-blade helicoid

polypropylene propeller, 29.4 cm air

passage per revolution

Distance Constant

2.7 m (8.9 ft.) for 63% recovery

Threshold Sensitivity 1.0 m/s (2.2 mph)

Output Signal

4-20 mA for 0 to 50 m/s (100 m/s optional)

Power Requirement: 10 to 30 VDC at 20 mA max

WIND DIRECTION (AZIMUTH) SPECIFICATION SUMMARY

Range

360° mechanical,

355° electrical (5° open)

Sensor

Balanced vane,

38 cm (15 in) turning radius.

Damping Ratio

0.3

Delay Distance

1.3 m (4.3 ft) for 50% recovery

Threshold Sensitivity 1.1 m/s (2.4 mph) at 10° displacement

Natural Wavelength

7.4 m (24.3 ft) Damped

7.2 m (23.6 ft) Undamped

Output Signal

4-20 mA for 0 to 360°

Power Requirement: 10 to 30 VDC at 20 mA max

GENERAL

Ambient Temperature -50 to 50°C (-58 to 122°F)

Intrinsic Safety

Class I, Division 1, Groups A, B, C, D

when installed with approved

Intrinsically Safe Barrier

(see Wiring Diagram)

Entity Approval

Vmax = 30V

Imax = 100 mA

Ci = 0.01 uF

Li = 0.0 uH

Advertising