3.3 JUMPERS

W1 JUMPERS A, B, and C, determine serial output format. Jumper

configurations and associated output format are listed below: 1 signifies

that jumper is installed, 0 signifies that jumper is omitted. See the SE-

RIAL FORMAT DIAGRAM in the Appendix for more details.

A B C

SERIAL OUTPUT FORMAT

0 0 0

ASCII Output

0 0 1

Polled ASCII

0 1 0

NMEA1

0 1 1

NMEA2

1 0 0

RMYT

1 0 1

PRECIP

1 1 0

PRECIP POLLED

1 1 1

SOFTWARE Mode

ASCII and RMYT formats force the serial baud rate to 9600. NMEA

formats force the baud rate to 4800.

ASCII and POLLED ASCII are general purpose outputs that may be

used with the YOUNG 26800 or devices that can communicate serially.

NMEA outputs are generally for marine applications. RMYT is a propri-

etary format for use with the YOUNG Wind Tracker.

PRECIP and PRECIP POLLED formats configure VIN4 to count tips

from a tipping bucket precipitation gauge. (Requires a 10K ohm resistor

between EXC and VIN4.)

SOFTWARE mode allows output format and other parameters to be set

using serial commands. Please see section 4.0 SERIAL COMMUNICA-

TION and the SERIAL FORMAT DIAGRAM for more information.

W2 & W3 JUMPERS determine output connection type. Only one

connection type may be used at a time. Please refer to the WIRING

DIAGRAM in the Appendix for jumper location and connection details.

JUMPERS

OUTPUT TYPE

VOUT

Calibrated output for wind speed and direction.

OUT1

0-5000mV = 0-100 m/s Wind Speed

OUT2

0-5000mV = 0-360 degrees Wind Direction

232

RS-232 full duplex serial

485

RS-485 half duplex serial

4.0 SERIAL COMMUNICATION

The 32500 uses either full-duplex RS-232 or half-duplex RS-485 signals

for serial communication. RS-232 is the most simple and operates up

distances of 30m (100ft). The RS-485 option is preferred in electri-

cally noisy environments, in applications where multiple units must be

networked, or in NMEA marine applications where RS-485 signals are

required.

The full duplex RS-232 connection may transmit and receive serial data

at the same time.

The RS-485 connection is half-duplex meaning the unit cannot transmit

and receive at the same time. The 32500 internally manages the switch

between modes.

Many applications require the 32500 to transmit only. However, RS-485

applications that require polling the 32500 or sending commands to it

require that the externally connected serial device must be capable of

managing its own half-duplex switching from transmit to receive.

At low baud rates with proper cable installation and connections, trans-

mission distances up to 7km (4mi) are possible using RS-485.

Baud rates of 1200, 4800, 9600, 19.2K, and 38.4K baud are available.

Most jumper-selected output formats force the baud rate to a predeter-

mined value. All serial signals use 1 start, 8 data, and 1 stop bit. Any

externally connected serial device must be set to the same baud rate as

the 32500.

4.1 POLLING

When the serial output format is ASCII POLLED or PRECIP POLLED,

the 32500 sends data only when it receives a serial polling command:

Ma!

where ‘a’ is the unique address of the unit. The default address is ‘A’ but

any alphanumeric character may be used (see POLLING CHARACTER

in section 4.2 SERIAL COMMANDS).

See the SERIAL FORMAT DIAGRAM for details on ASCII POLLED

data format.

4.2 SERIAL COMMANDS

Serial commands configure operating parameters and perform

calibrations.

While most W1 JUMPER settings configure the 32500 to use pre-

determined parameters, the SOFTWARE mode allows operational

parameters to be uniquely configured by serial commands. The

parameters are retained even when power is removed.

Commands may be sent using a PC and simple communications

programs such as HyperTerm or any other properly configured

serial device. All commands that begin with CMD must end with a

carriage return (ASCII 13).

Commands may be sent at any time but it may be more conve-

nient to pause 32500 serial output. This is especially necessary

with half-duplex RS-485 communication.

Command Description

CMD100

OPERATE

CMD110

PAUSE

CMD200 n

DAMPING (0=NONE, 1=FAST, 2=SLOW)

CMD210 n

FORMAT 0 ASCII

1 ASCII POLLED

2 NMEA (KTS, DIR)

3 NMEA (KTS, DIR, TEMP, RH, BARO

4 RMYT

5 PRECIP

6 PRECIP POLLED

7 ASCII 2

9 DIAGNOSTIC

CMD220 n

OUTPUT RATE (0=15Hz, 1=0.1Hz, 2=2Hz)

CMD230 c

POLL CHARACTER (0-9, A-Z)

CMD240 nn BAUD RATE

(12=1200, 48=4800, 96=9600, 192=19200,

384=38400)

CMD250 n

INPUT TYPE (1=PULSE/POT, 2=VIN3/VIN4)

CMD900

REPORT PARAMETER SETTINGS

CMD910

START COMPASS CALIBRATION

CMD920

STOP COMPASS CALIBRATION

X

Alternative command to enter OPERATE mode

3xESC

Alternative command to PAUSE

3xCNTL-S

Alternative command to START compass cali-

bration

3xCNTL-X

Alternative command to STOP compass cali-

bration

DAMPING determines the amount of averaging applied to the

compass measurement.