RADWAG E2R Weighing Records User Manual

Page 18

Advertising
background image

Synch_Towar
MasaEnabled

0

Setting parameter to „1” causes enabling the
update of mass standard in the scale

Synch_Towar
MinMaxEnabled

0

Setting parameter to „1” causes enabling the
update of thresholds in the scale

Synch_Towar
TaraEnabled

0

Setting parameter to „1” causes enabling the
update of tare in the scale

Synch_Towar
UpdateEnabled

0

Setting parameter to „1” causes enabling the
update of tare in the scale

ReconnectTimeout
OnNoRespond

0

A parameter for setting the maximum timeout
in seconds (waiting for a scale reply). After the
time elapses the scale is disconnected and
reconnected to Synchronizer.
Parameter values:
0 – no timeout, 1 to 60 – timeout in seconds.

Signalling lamp

0

Setting parameter to „1” sets the
checkweighing mode of a scale based on
indicator PUE4-L

After making changes (adding scales and changing parameters) press
button „Save”.

18