CS1615/16

DS961F1

5

Notes:

1. The CS1615/16 has an internal shunt regulator that limits the voltage on the VDD pin. Shunt regulation voltage V

Z

is defined in

the VDD Supply Voltage section on page 4.

2. For test purposes, load capacitance C

L

is connected to pin GD and is equal to 0.25nF.

3. External circuitry should be designed to ensure that the ZCD current drawn from the internal clamp diode when it is forward biased

does not exceed specification.

4. Protection is implemented using pin FBSENSE. See the CS1615/16 Block Diagram on page 2.
5. Protection is implemented using pin FBAUX. See the CS1615/16 Block Diagram on page 2
6. The conductance is specified in Siemens (S or 1/

). Each LSB of the internal ADC corresponds to 250nS or one parallel 4M

resistor. Full scale corresponds to 256 parallel 4M

 resistors or 15.625k.

7.

Specifications are guaranteed by design and are characterized and correlated using statistical process methods.

Flyback/Buck-boost Protections
Overcurrent Protection (OCP)

(Note 4)

V

OCP(th)

-

1.69

-

V

Overvoltage Protection (OVP)

(Note 5)

V

OVP(th)

-

1.25

-

V

Open Loop Protection (OLP)

(Note 4)

V

OLP(th)

-

200

-

mV

External Overtemperature Protection (eOTP)
Pull-up Current Source – Maximum

I

CONNECT

-

80

-

A

Conductance Accuracy

(Note 6)

-

-

±5

Conductance Offset

(Note 6)

-

±250

-

nS

Current Source Voltage Threshold

V

CONNECT(th)

-

1.25

-

V

Internal Overtemperature Protection (iOTP)
Thermal Shutdown Threshold

(Note 7)

T

SD

-

135

-

ºC

Thermal Shutdown Hysteresis

(Note 7)

T

SD(Hy)

-

14

-

ºC

Parameter

Condition

Symbol

Min

Typ

Max

Unit

Advertising