9. CONDUCTED EMI

Device Under Test: CRD1615-8W-Z

Operating Conditions: NOMINAL

Test Specification: EN55022:2010

Operator Name: CAL

Scan Settings (1 Range)

Final Measurement

Detectors: QP, AV

Peaks: 10

Meas Time: See scan settings

Acc. Margin: 12dB

Final Measurement Results

Frequencies

Receiver Settings

Start

Stop

Step

Res BW

M-Time

Atten

Preamp

150kHz

30MHz

4.5kHz

9kHz (6dB)

50ms

Auto

Off

Trace

Frequency

(MHz)

Level

(dB

V)

Limit

(dB

V)

Delta Limit

(dB)

Delta Ref

(dB)

Comment

1QP

0.15

58.05

66.00

-7.95

N/on

2AV

10.0005

41.04

50.00

-8.96

N/on

* = Limit Exceeded

Figure 21. Conducted EMI