8 configuration default, P 119, Cs4207 – Cirrus Logic CS4207 User Manual

Page 119

Advertising
background image

DS880F4

119

CS4207

6.13.8

Configuration Default

The Configuration Default register is used by software as an aid in determining the configuration of jacks
and devices attached to the codec. At the time the codec is first powered on, this register is internally load-
ed with default values indicating the typical system use of this particular pin/jack. After this initial loading,
it is completely codec opaque, and its state, including any software writes into the register, must be pre-
served across reset events such as Link Reset or Codec Reset (the Function Reset Verb). Its state need
not be preserved across power level changes.

Get Parameter Command Format:

Set Parameter Command Format:

Response Format:

Bits [31:0] are sticky and will not be reset by a Link Reset or a Codec Reset:

Bits [31:28]

Bits [27:20]

Bits [19:8]

Bits [7:0]

CAd = X

Node ID = 0Fh

Verb ID = F1Ch

Payload = 00h

Bits [31:28]

Bits [27:20]

Bits [19:8]

Bits [7:0]

CAd = X

Node ID = 0Fh

Verb ID = 71Ch

Payload = xxh (Config bits [7:0])

CAd = X

Node ID = 0Fh

Verb ID = 71Dh

Payload = xxh (Config bits [15:8])

CAd = X

Node ID = 0Fh

Verb ID = 71Eh

Payload = xxh (Config bits [23:16])

CAd = X

Node ID = 0Fh

Verb ID = 71Fh

Payload = xxh (Config bits [31:24])

Bits

Type

Default

Description

31:30

Read/Write

00b

Port Connectivity (PCON): The port complex is
connected to a jack.

29:24

Read/Write

000010b

Location (LOC): This field indicates the physical
location of the jack or device to which the pin
complex is connected. Set to External | Front.

23:20

Read/Write

Ch

Default Device (DD): Indicates the intended use
of the connection is for S/PDIF In.

19:16

Read/Write

4h

Connection Type (CTYP): Indicates the type of
physical connection is RCA jack.

15:12

Read/Write

Eh

Color (COL): This field indicates the color of the
physical jack for use by software. The color
selected is White.

11:8

Read/Write

0h

Miscellaneous (MISC): No PDC override.

7:4

Read/Write

Fh

Default Association (DA): This field is used by
software to group Pin Complex (and therefore
jacks) together into functional blocks to support
multichannel operation. All jacks with the same
association number may be assumed to be
grouped together. A value of all ‘0’s is reserved.
A value of all ‘1’s in this field indicates that the
Association has the lowest priority.

3:0

Read/Write

0h

Sequence (SEQ): This field indicates the order
of the jacks in the association group.

Advertising