SWITCHING CHARACTERISTICS - INTERNAL SERIAL CLOCK

Notes: 6. The Duty Cycle must be 50%

+/− 1/2 MCLK Period.

7. See section 4.2.1 for derived internal frequencies.

Parameters

Symbol Min Typ

Max

Units

MCLK Frequency

1.024

-

51.2

MHz

MCLK Duty Cycle

45

-

55

%

Input Sample Rate

Single-Speed Mode

Double-Speed Mode

Fs
Fs

4

50

-
-

50

100

kHz
kHz

LRCK Duty Cycle

(Note 6)

%

SCLK Period

(Note 7)

t

sclkw

-

-

s

SCLK rising to LRCK edge

t

sclkr

-

-

s

SDATA valid to SCLK rising setup time

t

sdlrs

-

-

ns

SCLK rising to SDATA hold time

MCLK / LRCK = 512, 256 or 128

t

sdh

-

-

ns

SCLK rising to SDATA hold time

MCLK / LRCK = 384 or 192

t

sdh

-

-

ns

1

SCLK

----------------

t

sclkw

2

--------------

1

512

(

)Fs

----------------------

10

+

1

512

(

)Fs

----------------------

15

+

1

384

(

)Fs

----------------------

15

+

SDATA

*INTERNAL SCLK

LRCK

sclkw

t

sdlrs

t

sdh

t

sclkr

t

Figure 12. Internal Serial Mode Input Timing

*

The SCLK pulses shown are internal to the CS4341.

SDATA

LRCK

MCLK

*INTERNAL SCLK

1

N
2

N

Figure 13. Internal Serial Clock Generation

*

The SCLK pulses shown are internal to the CS4341. N equals MCLK divided by SCLK