Figure 6. control port timing - spi format, Figure 6.control port timing - spi format – Cirrus Logic CS4385 User Manual

Page 18

Advertising
background image

18

DS671F2

CS4385

SWITCHING CHARACTERISTICS - CONTROL PORT - SPI FORMAT

Inputs: Logic 0 = GND, Logic 1 = VLC, C

L

= 20 pF.

Notes:

19. t

spi

is only needed before first falling edge of CS after RST rising edge. t

spi

= 0 at all other times.

20. Data must be held for sufficient time to bridge the transition time of CCLK.

21. For F

SCK

< 1 MHz.

Parameter

Symbol

Min

Max

Unit

CCLK Clock Frequency

f

sclk

-

6

MHz

RST Rising Edge to CS Falling

t

srs

500

-

ns

CCLK Edge to CS Falling

(Note 19)

t

spi

500

-

ns

CS High Time Between Transmissions

t

csh

1.0

-

µs

CS Falling to CCLK Edge

t

css

20

-

ns

CCLK Low Time

t

scl

66

-

ns

CCLK High Time

t

sch

66

-

ns

CDIN to CCLK Rising Setup Time

t

dsu

40

-

ns

CCLK Rising to DATA Hold Time

(Note 20)

t

dh

15

-

ns

Rise Time of CCLK and CDIN

(Note 21)

t

r2

-

100

ns

Fall Time of CCLK and CDIN

(Note 21)

t

f2

-

100

ns

t r2

t f2

t dsu t dh

t sch

t scl

CS

CCLK

CDIN

t css

t csh

t spi

t srs

RST

Figure 6. Control Port Timing - SPI Format