Digital characteristics, Absolute maximum ratings, Recommended operating conditions – Cirrus Logic CS4396 User Manual

Page 7: Cs4396

Advertising
background image

CS4396

DS288PP1

7

DIGITAL CHARACTERISTICS

(T

A

= 25°C; VD = 3.0V - 5.25V)

ABSOLUTE MAXIMUM RATINGS

(AGND = 0 V, all voltages with respect to ground.)

WARNING: Operation at or beyond these limits may result in permanent damage to the device. Normal operation
is not guaranteed at these extremes.

RECOMMENDED OPERATING CONDITIONS

(DGND = 0V; all voltages with respect to ground)

Parameters

Symbol Min Typ

Max

Units

High-Level Input Voltage

VD = 5 V
VD = 3 V

V

IH

2.0
2.0

-
-

-
-

V
V

Low-Level Input Voltage

VD = 5 V
VD = 3 V

V

IL

-
-

-
-

0.8
0.8

V
V

Input Leakage Current

I

in

-

-

±10

µ

A

Input Capacitance

-

8

-

pF

Maximum MUTEC Drive Current

-

3

-

mA

Parameter

Symbol Min

Max

Unit

DC Power Supply: Positive Analog

Positive Digital
Reference Voltage

VA

VD

VREF

-0.3
-0.3
-0.3

6.0
6.0

VA

V
V
V

Input Current, Any Pin Except Supplies

I

in

-

±10

mA

Digital Input Voltage

V

IND

-0.3

(VD)+0.4

V

Ambient Operating Temperature (power applied)

T

A

-55

125

°C

Storage Temperature

T

stg

-65

150

°C

Parameter

Symbol Min Typ

Max

Unit

DC Power Supply: Positive Digital

Positive Analog
Reference Voltage

VD

VA

VREF

3.0

4.75
TBD

3.3
5.0
5.0

5.25
5.25

VA

V
V
V

Specified Temperature Range

T

A

-10

-

70

°C

Advertising