3 pcmx overflow (read only), 27 battery compensation (address 2fh), 1 battery compensation – Cirrus Logic CS43L22 User Manual

Page 56: 2 vp monitor, 1 battery compensation 7.27.2 vp monitor, P 56

Advertising
background image

56

DS792F2

CS43L22

Confidential Draft

3/4/10

7.26.3

PCMx Overflow (Read Only)

Indicates the over-range status in the PCM data path.

7.27

Battery Compensation (Address 2Fh)

7.27.1

Battery Compensation

Configures automatic adjustment of the speaker volume when VP deviates from VPREF[3:0].

7.27.2

VP Monitor

Configures the internal ADC that monitors the VP voltage level.

Notes:

1.

The internal ADC that monitors the VP supply is enabled automatically when BATTCMP is enabled, re-
gardless of the VPMONITOR setting. Conversely, when BATTCMP is disabled, the ADC may be en-
abled by enabling VPMONITOR; this provides a convenient battery monitor without enabling battery
compensation.

2.

When enabled, VPMONITOR remains enabled regardless of the PDN bit setting.

PCMxOVFL

PCM Overflow Status:

0

No digital clipping has occurred in the data path of the PCM (

“PCM Channel x Volume” on page 47

) of the

DSP.

1

Digital clipping has occurred in the data path of the PCM of the DSP.

Application:

“DSP Engine” on page 21

7

6

5

4

3

2

1

0

BATTCMP

VPMONITOR

Reserved

Reserved

VPREF3

VPREF2

VPREF1

VPREF0

BATTCMP

Automatic Battery Compensation

0

Disabled

1

Enabled

Application:

“Maintaining a Desired Output Level” on page 27

VPMONITOR

VP ADC Status

0

Disabled

1

Enabled

Advertising