System design with cs5376a, 1 power supplies, 2 reset control – Cirrus Logic CS5376A User Manual

Page 19: Power supplies 3.2. reset control, Figure 9. multi-channel system block diagram, Cs5376a

Advertising
background image

CS5376A

DS612F4

19

3. SYSTEM DESIGN WITH CS5376A

Figure 9 illustrates a simplified block diagram of
the CS5376A in a multi-channel measurement sys-
tem.

Up to four differential sensors are connected
through CS3301A/02A differential amplifiers to
the CS5371A/72A

∆Σ modulators, where analog to

digital conversion occurs. Each modulators 1-bit
output connects to a CS5376A MDATA input,
where the oversampled

∆Σ data is decimated and

filtered to 24-bit output samples at a programmed
output rate. These output samples are buffered in
an 8-deep data FIFO and passed to the system te-
lemetry on command.

System self tests are performed by connecting the
CS5376A test bit stream (TBS) generator to the
CS4373A test DAC. Analog tests drive differential
signals from the CS4373A test DAC into the mul-
tiplexed inputs of the CS3301A/02A amplifiers or

directly to the sensors through external analog
switches. Digital loopback tests internally connect
the TBS digital output directly to the CS5376A
modulator inputs.

3.1 Power Supplies

The multi-channel system shown in Figure 9 typi-
cally operates from a

±

2.5 V analog power supply

and a 3.3 V digital power supply. The CS5376A
logic core can be powered from 3 V to minimize
power consumption, if required.

3.2 Reset Control

System reset is required only for the CS5376A de-
vice, and is a standard active low signal that can be
generated by a power supply monitor or microcon-
troller. Other system devices default to a power-
down state when the CS5376A is reset.

Figure 9. Multi-Channel System Block Diagram

∆Σ

Modulator

∆Σ

Modulator

Digital Filter

AMP

AMP

AMP

AMP

Geophone

or

Hydrophone

Sensor

Geophone

or

Hydrophone

Sensor

Geophone

or

Hydrophone

Sensor

Geophone

or

Hydrophone

Sensor

M
U
X

M
U
X

M
U
X

M
U
X

Test

DAC

µController

or

Configuration

EEPROM

Communication

Interface

CS3301A
CS3302A

CS5371A

CS5371A

CS5376A

CS4373A

System Telemetry

CS5372A

CS5372A

Switch

MUX

Switch

MUX

CS3301A
CS3302A

CS3301A
CS3302A

CS3301A
CS3302A

Advertising