1. CHARACTERISTICS AND SPECIFICATIONS
1.1 Recommended Operating Conditions

1.2 Electrical Characteristics

Parameter

Symbol Min Typ

Max

Unit

Reference
Line Voltage

V

AC

90

-

260

V

Load Current

I

RMS

-

-

15

A

Peak Current

I

PEAK

-

-

22

A

Fundamental Frequency

Freq

5

-

2000

Hz

Ambient Operating Temperature

T

A

-40

85

C

Parameter

Symbol Min Typ

Max

Unit

Reference
Power Consumption (V

AC

= 240V, 50Hz)

P

AC

-

0.6

-

W

Accuracy (PF=1, Sample Count 8000 - 2 second, Temp Compensation Enabled)
RMS Voltage (90-260V

AC

)

V

RMS

-

0.1

-

%

RMS Current (15mA-15A)

I

RMS

-

0.1

-

%

Active Power (1.5W-3900W)

P

AVG

-

0.1

-

%