Basic application circuits, Figure 25. typical connection, Cs5484 – Cirrus Logic CS5484 User Manual

Page 65: L1 l2 n, Application processor

Advertising
background image

CS5484

DS981F3

65

8. BASIC APPLICATION CIRCUITS

Figure 25

shows the CS5484 configured to measure

power in a single-phase, 3-wire system with two
voltages and two currents. In this diagram, current

transformers (CTs) are used to sense the line load
currents, and resistive voltage dividers are used to
sense the line voltage.

CT

CT

5 x 250K

1K

CS5484

27nF

27nF

1K

1K

L1

L2

N

VIN2-

VIN2+

IIN1+

IIN1-

IIN2+

IIN2-

Application

Processor

RESET

RX

TX

GNDA GNDD

DO3

DO1

DO2

VDDA

+3.3V

0.1uF

0.1uF

+3.3V

VDDD

+3.3V

VREF-

VREF+

0.1uF

27nF

27nF

1K

1K

½ R

BURDEN

Wh

Varh

4.096MHz

XIN

XOUT

27nF

27nF

1K

SSEL

Interrupt

½ R

BURDEN

½ R

BURDEN

½ R

BURDEN

MODE

VIN1+

VIN1-

27nF

27nF

1K

5 x 250K

1K

Zero Crossings

DO4

+3.3V

LOA D

LOA D

0.1 uF

10K

+3.3V

CS

Figure 25. Typical Connection (Single-phase, 3-wire, 12S Electricity Meter)

Advertising