DS206DB2

5

CDB8952

Crystal LAN™ 10Base-T and 100Base-X Transceiver

CIRRUS LOGIC ADVANCED PRODUCT DATABOOK

3.3V Power Supply Option

Outlined below are several different way to supply
power to the CDB8952 evaluation board.

5 V Supplied Through the MII Connector - When
the CDB8952 is connected to a system which sup-
plies +5 V through the MII connector, J5 and J6
may be connected together via a short cable. Alter-
natively, J6 may be connected to an external +5 V
supply and J5 left unconnected.

NOTE: Under no circumstances should J5 be con-

nected to an external power supply if power is
also supplied through the MII connector.

3.3V Supplied Through the MII Connector -When
the CDB8952 is connected to a system which sup-
plies +3.3 V through the MII connector, J6 must be
connected to an external +5 V supply and J5 left
unconnected.

No Power Supplied Through the MII Connector -
When the CDB8952 is connected to a system
which does not supply power through the MII con-
nector, J5 and J6 may both be connected to a single
external +5 V supply. Alternatively, J5 may be
connected to an external +3.3V supply and J6 to an
external +5 V supply.

100Base-FX Interface Option

The CDB8952 board has been designed to accom-
modate a Hewlett Packard HFBR-5103 Fiber
Transceiver Module.

BOARD ASSEMBLY NOTES

Magnetics Vendors

Crystal Vendors

Fiber Module Vendors

NETCOM X-1000 TEST NOTE

The Netcom X-1000 Fast Ethernet Tester has been
known to assert TX_EN during power up or when
an MII transceiver is hot plugged into the device.
This does not comply with the IEEE 802.3u-1995
specification, paragraph 22.2.2.3 TX_EN (transmit
enable). The CS8952 will fail to generate TX_CLK
following its power-on reset sequence under either
of these conditions. This was intended to keep the
CS8952 from sending runt packets onto the net-
work at power-on.

Vendor

Part Number

Bel Fuse Inc.
198 Van Vorst St.
Jersey City, NJ 07302
(201) 432-0463
www.belfuse.com

S558-5999-46

Halo Electronics, Inc.
P.O.Box 5826
Redwood City, CA 94063
(650) 568-5800
www.haloelectronics.com

TG22-3506ND

Pulse Engineering, Inc.
12220 World Trade Dr.
San Diego, CA 92128
(619) 674-8100
www.pulseeng.com

PE-68515

Vendor

Part Number

Raltron Electronics Corp.
10651 NW 19th St.
Miami, FL 33172
(305) 593-6033
www.raltron.com

AS-25.000-15-F-

EXT-SMD-TR-CIR

Vendor

Part Number

Hewlett Packard Components

Sales Response Center
(408) 654-8675

www.hp.com/HP-COMP

HFBR-5103