Setting up for management – Asante Technologies 5308F User Manual

Page 40

Advertising
background image

Installation

Page 2-12

Setting up for

Management

To use the IntraSwitch 5308FL as a managed switch, it must be
configured with an IP address. This can be accomplished in
one of two ways:

automatically using BootP (default)

manually via the Console port

BootP

Configuration

The IntraSwitch 5308FL is shipped with BootP/TFTP support.
BootP allows the IntraSwitch 5308FL to be automatically
configured with an IP address when it is connected to the
network and is powered on, if your network contains a BootP
server configured with available, valid IP addresses.

Important! BootP configuration only works if
the IntraSwitch 5308FL does not have an IP
address already assigned to it.

1

Make sure your network has a BootP server con-
figured with a valid IP address entry for the
IntraSwitch 5308FL.

2

When the IntraSwitch 5308FL is connected to
the network and is powered on, it automatically
transmits a BootP request across the network
(up to

5 times) until it receives a valid IP address

from the BootP server.

3

After an IP address is received, the IntraSwitch
5308FL can be managed via in-band access.

See Chapter 4 for information on connecting to
the IntraSwitch 5308FL for management.

To verify that the IntraSwitch 5308FL received
an IP address, use a tool such as Ping

1

to try and

access the IntraSwitch 5308FL; if you can access
the IntraSwitch 5308FL, it is properly config-
ured with an IP address.

1. Ping (an acronym for packet internet groper) is an application that can be used to

test whether a remote device is properly connected to a network.