Switch settings, Parts list – CPI Communications DTP Series User Manual

Page 3

Advertising
background image

3

Switch Settings

The following table lists dip switch setting for DTP series.

Dip switch 4 is normally in the OFF position. When in the ON position, The perceived polarity of the phone
lines is reversed.
Modulation output is adjustable from 2 mVRMS to 565 mVRMS with 0 dBm on the phone lines. The phone
lines can be driven to 0 dBm with an RX input level from 88 mVRMS to 880 mVRMS. A 0 dBm level on the
phone line back to the remote can be produced with a mic high input between 2 mVRMS and 565 mVRMS.

Parts List

DTP Series PCB #700-DTPX-200 Rev. B

Reference

Description

CPI Part #

CAPACITORS

C1,18

100uF Elec Rad

208-2021-107

C2,3,5,15,16

.1uF Mono Cer Dip

208-0092-104

C4

10uF Elec Rad

208-4022-106

C6,27

1uF Elec Rad

208-4052-105

C9,10

4.7uF 100V Elec Rad

208-2062-475

C11,12

20pF Cer

208-0001-200

C13,14,17,21,22

.01uf Mono Cer Dip

208-0092-103

C23

180pF Mono Cer Dip

208-0071-181

C24

.047 Mono Cer Dip

208-0092-473

C25

2200pF Mono Cer Dip

208-0071-222

C26

1uF Elec Rad Non-Polar

208-2000-001

C28

2.2uF Elec Rad

208-4052-225

DC Remote Provides

Set Switches

PTT (F1)

PTT (F2)

Mon (F1)

Mon (F2)

1

2

3

DTP1, DTP2

& DTP3

+/- 15mA

OFF

OFF

OFF

+/- 6mA

ON

OFF

OFF

DTP2 & DTP3

+/- 15mA

+/- 6mA

OFF

ON

OFF

+ 15mA

-6 mA

ON

ON

OFF

+/- 6mA

+/- 2.5mA

OFF

OFF

ON

+ 6mA

- 2.5mA

ON

OFF

ON

DTP3

+ 6mA

+ 15mA

- 2.5mA

- 2.5mA

OFF

ON

ON

+ 15mA

- 15mA

+ 6mA

- 6mA

ON

ON

ON